Description
Details
Manufacturer: APC
Model: APC Smart-UPS RT 6000VA 4200W Tower 220-240V
Condition: New batteries, refurbished UPS
Part Number: SURT6000XLI
Maximum output: 4200W / 6000VA
Typical backup time at half load: 15.5 minutes (2100 Watts)
Typical backup time at full load: 5.1 minutes (4200 Watts)
Warranty: 1 year full replacement warranty
APC Smart-UPS RT 6000VA 4200W Tower 230V SURT6000XLI Manual
SURT6000XLI - APC Smart-UPS RT 6000VA Specifications:
Main:
Main Input Voltage |
230V |
||||||
Other Input Voltage |
220V |
||||||
Main Output Voltage |
230V |
||||||
Other Output Voltage |
220V |
||||||
Rated Power in W |
4200W |
||||||
Rated Power in VA |
6000VA |
||||||
Output Connection Type |
|
||||||
Number of Rack Unit |
3U |
||||||
Battery Type |
Lead-acid Battery |
General:
Number of Power Module Free Slots |
0 |
Number of Power Module Filled Slots |
0 |
Redundant |
No |
Physical:
Colour |
Black |
Height |
43.2 cm |
Width |
13 cm |
Depth |
66 cm |
Net Weight |
54.43 kg |
Mounting Location |
Front |
Mounting Preference |
Lower |
Mounting Mode |
Not rack-mountable |
Two Post Mountable |
0 |
USB Compatible |
No |
Input:
Network Frequency |
50/60 Hz +/- 5 Hz auto-sensing |
Number of Input Connectors |
1 hard wire 3-wire |
Input Voltage Limits |
160 - 280V |
Output:
Maximum Configurable Power in W |
4200W |
Harmonic Distortion |
Less than 3% |
Output Frequency |
50/60 Hz +/- 3 Hz user adjustable +/- 0.1 Hz sync to mains |
Crest Factor |
3:1 |
UPS Type |
Double Conversion Online |
Wave Type |
Sine wave |
Bypass Type |
Internal Bypass (Automatic and Manual) |
Maximum Configurable Power in VA |
6000VA |
Conformance:
Product Certifications |
C-Tick |
Standards |
EN/IEC 62040-1:2019/A11:2021 |
Environmental:
Ambient Air Temperature for Operation |
0 - 40°C
|
Relative Humidity |
0 - 95% non-condensing |
Operating Altitude |
0 - 10000 ft |
Ambient Air Temperature for Storage |
-15 - 45°C |
Storage Relative Humidity |
0 - 95% non-condensing |
Storage Altitude |
0.00 - 15240.00 m |
Acoustic Level |
55 dBA |
Heat Dissipation |
1221 Btu/h |
IP Degree of Protection |
IP20 |
Batteries & Runtime:
Number of Battery Filled Slots |
2
|
Battery Recharge Time |
2.5 h |
Number of Battery Replacement Quantity |
1 |
Additional Information |
Configurable for 220: 230 or 240 Nominal Output Voltage |
Battery Charger Power |
421 W rated |
Battery Power in VAH |
1056 VAh Runtime |
Battery Life |
3 - 5 year(s) |
Replacement Battery |
APCRBC140 |
Battery Option |
SURT192XLBP 1 2304 VAh |
Extended Runtime |
1 |
Communications & Management:
Free Slots |
0
|
Preinstalled Device |
Network Management Card 3 with Environmental Monitoring |
Alarm |
Alarm when on battery: distinctive low battery alarm: overload continuous tone alarm |
Emergency Power Off |
Yes |
Surge Protection and Filtering:
Surge Energy Rate |
555 J
|
Noise Suppression |
Full time multi-pole noise filtering: 0.3% IEEE surge let-through: zero clamping response time: meets UL 1449 |
Additional Info
Additional Info
Manufacturer | APC |
---|---|
Form Factor | Tower |
Waveform in Battery Mode | Pure Sinewave |
Input Voltage | 208V AC, 230V AC (EU), 240V AC |
Output (VA) | 6000VA |
Output Voltage | 208V AC, 230V AC (EU), 240V AC |
PDU Total Outlets | No |