Call toll free: 1-866-311-1945 | sales@excessups.ca
Your Region:

Tripp Lite SmartPro UPS 5000VA 4000W RM 6U 208/120V SMART5000RT3U - Refurbished

Tripp Lite SmartPro UPS 5000VA 4000W RM 6U
Model: SMART5000RT3U
Input: NEMA L6-30P (208V - 30A)
Output: (10) NEMA 5-15R, (2) NEMA 5-20R, (1) NEMA L6-30R, (1) NEMA L14-30R
Line-Interactive UPS - Pure Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
CAD $2,749.99
Availability: In stock

Description

Details

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartPro UPS 5000VA 4000W, RM, 30A, 208/120V
Condition:
New batteries, refurbished UPS
Part Number:
SMART5000RT3U

Maximum output: 4000W / 5000VA
Typical backup time
at half load: 38 minutes (2000 Watts)
Typical backup time
at full load: 16 minutes (4000 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartPro 5000VA 4000W RM 6U 208/120V SMART5000RT3U Manual


SMART5000RT3U - Tripp Lite SmartPro 5000VA Specifications:

Input:

Rated input current (Maximum Load)

24A max. in factory L6-30P configuration; 27A max. when powered by 50A plug or hardwire input

Nominal Input Voltage(s) Supported

208V AC

UPS Input Connection Type

NEMA L6-30P

Input Circuit Breakers

30A double-pole

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Recommended Electrical Service

30A 208V

Input Phase

Single-Phase


Output:

Output Volt Amp Capacity (VA)

5000

Output kVA Capacity (kVA)

5

Output Watt Capacity (Watts)

4000

Output kW Capacity (kW)

4

Output Capacity Details

Maximum output increases to 4800W when hardwire or user-supplied 50A rated input plug is used

Power Factor

0.8

Nominal Voltage Details

208/208/120V nominal output in battery mode

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode)

208 & 208/120V (-10%, +20%)

Output Voltage Regulation (Battery Mode)

+/- 5%

Load Management Receptacles

Eight switchable single-outlet 5-15R load banks

Output Circuit Breakers

15A branch rated (x3) - 2 breakers support 5 5-15R outlets each, one breaker supports 2 5-20R outlets, L6-30R and L14-30R outlets are unbreakered

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

110V; 115V; 208/120V; 208V

Output Receptacles

(10) NEMA 5-15R

 (2) NEMA 5-15/20R

 (1) NEMA L14-30R


 (1) NEMA L6-30R


Individually Controllable Load Banks

Yes


Battery:

Full Load Runtime (min.)

16 min. (4000w)

Half Load Runtime (min.)

38 min. (2000w)

Expandable Battery Runtime

Extended runtime supported via optional external battery packs

External Battery Pack Compatibility

BP48V24-2U  (limit 1);  BP48V60RT-3U  (multi-pack compatible);  BP48V27-2US  (multi-pack compatible)

DC System Voltage (VDC)

48

Battery Recharge Rate (Included Batteries) 

Less than 4 hours from 10% to 90% (typical, full load discharge)

Internal UPS Replacement Battery Cartridge

RBC94-2U

Battery Replacement Description

Hot-swappable, user replaceable batteries

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 151 to 282

Overvoltage Correction

Input voltages between 240V and 260 are reduced by 12%

Undervoltage Correction

Input voltages between 180V and 199 are boosted by 12%

Severe Undervoltage Correction 

Input voltages between 151V and 179 are boosted by 24%


User Interface, Alerts & Controls:

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate lowbattery status

Audible Alarm

Audible alarm indicates power-failure, overload and low-battery conditions

LED Indicators 

5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

1020

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fans

Included Battery Pack Dimensions
(hwd / in.)

5.2 x 17.5 x 25

Included Battery Pack Weight (kg)

73.94

Included Battery Pack Weight (lbs.)

163

Included Mounting Accessory Description 

Set of two included 4POSTRAILKIT mounting brackets enables installation of UPS and Battery Pack in 4 post racks from 20.5 to 36 inches (521 to 914mm)

Installation Form Factors Supported with Included Accessories

4 post 19 inch rackmount

Installation Form Factors Supported
with Optional Accessories

2 post rackmount ( 2POSTRMKITHD ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2-9USTAND )

Minimum Required Rack Depth with
External Battery Pack (cm)

72

Minimum Required Rack Depth with
External Battery Pack (in.)

28.25

Minimum Required Rack Depth
without External Battery Pack (cm)

62

Minimum Required Rack Depth
without External Battery Pack (in.)

24.46

Optional Mounting Accessory Notes

Optional  2-9USTAND  enables upright tower UPS placement (1 required);  2POSTRMKITHD  enables 2-post rackmount installation (2 required);  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm, requires 2)

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

572

Primary UPS Height (mm)

132

Primary UPS Width (mm)

445

Rack Height

6U

Shipping Dimensions (hwd / cm)

62.23 x 60.96 x 86.36

Shipping Dimensions (hwd / in.)

24.50 x 24.00 x 34.00 

Shipping Weight (kg)

145.88

Shipping Weight (lbs.)

321.62

Unit Dimension Details

Includes 3U UPS/power module and 3U external battery pack

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

13.21 x 44.45 x 57.15

UPS Power Module Dimensions (hwd, in.)

5.2 x 17.5 x 22.5

UPS Power Module Weight (kg)

42.18

UPS Power Module Weight (lbs.)

93 

 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

Battery Mode BTU / Hr. (Full Load)

1518

AC Mode Efficiency Rating (100% Load)

94%

Audible Noise

45 dBA maximum, front side 1m


Communications:

Network Management Cards

SNMPWEBCARD ;  WEBCARDLX

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; 2 USB ports, 1 DB9 serial and 1 DB9 contact closure port (4 total)

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Communications Interface

Contact closure; DB9 Serial; USB

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 208V AC
Output (VA) 5000VA
Output Voltage 120V AC, 208V AC
PDU Total Outlets No