Call toll free: 1-866-311-1945 | sales@excessups.ca
Your Region:

Tripp Lite SmartOnline 5000VA 3500W RM 7U 208V SU5000RT3U - Refurbished

Tripp Lite SmartOnline 5000VA 3500W RM 7U
Model: SU5000RT3U
Input: NEMA L6-30P (120V - 30A)
Output: (12) NEMA 5-15/20R, (2) NEMA L6-20R, (2) NEMA  L6-30R
Double Conversion Online UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
  • 1 Year Included
    Included
  • 2 Year
    +CAD $330.00
  • 3 Year
    +CAD $577.50

* Required Fields

CAD $1,649.99
Availability: In stock

Description

Details

Love Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 5000VA 3500W, RM, 7U, 208V, New Batteries, Refurbished UPS
Condition:
New batteries, refurbished UPS
Part Number:
SU5000RT3U

Maximum output: 3500W / 5000VA
Typical backup time
at half load: 20 minutes (1750 Watts)
Typical backup time
at full load: 8 minutes (3500 Watts)
Warranty:
1 year full replacement warranty
Included: UPS, Step Down, Battery cabinet


Tripp Lite SmartOnline 5000VA 3500W RM 7U 208V SU5000RT3U User's Manual


SU5000RT3U - Tripp Lite SmartOnline 5000VA Specifications:

Input:

Rated input current (Maximum Load)

24A (208V)

Nominal Input Voltage(s) Supported

208V AC

UPS Input Connection Type

L6-30P

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Recommended Electrical Service

30A 208V

Input Phase

Single-Phase

Output:

Output Volt Amp Capacity (VA)

5000

Output kVA Capacity (kVA)

5

Output Watt Capacity (Watts)

3500

Output kW Capacity (kW)

3.5

Power Factor

0.7

Crest Factor

3:1

Nominal Voltage Details

This configuration requires the Power Module be set to 208V output voltage; Included step-down transformer
supports 120V output

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Output frequency matches input nominal on startup

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Output Circuit Breakers

20A breakers (x4) on transformer module protect 3 5-15/20R outlets each, 20A breaker on power module protects L6-20R outlets, L6-30R outlets are unbreakered

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Output Capacity Details

Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared

Nominal Output Voltage(s) Supported

120V; 208V

Output Receptacles

(12) NEMA  5-15/20R

 

(2) NEMA L6-20R

(2) NEMA  L6-30R

Individually Controllable Load Banks

No


Battery:

Full Load Runtime (min.)

8 min. (3500W)

Half Load Runtime (min.)

20 min. (1750w)

Expandable Battery Runtime

Supports extended runtime with optional external battery packs

External Battery Pack Compatibility

 BP240V10RT3U ; BP240V557C-1PH;  BP240V787C-1PH ; BP240V1037C1PH; BP240V1407C-1PH

DC System Voltage (VDC)

240

Battery Recharge Rate (Included Batteries) 

Less than 6 hours from 10% to 80% (typical, full load discharge)

Battery Replacement Description

Hot-swappable, user replaceable batteries

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

2% output voltage regulation during overvoltages to 276

Undervoltage Correction

2% output voltage regulation during undervoltages to 130


User Interface, Alerts & Controls:

Front Panel LCD Display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions

Alarm Cancel Operation

Alarm cancel switch

Audible Alarm

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCDscreen offers additional information and control options


Surge / Noise Suppression:

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Battery Pack Dimensions (hwd / in.)

3.5 x 17.5 x 22.5

Included Battery Pack Weight (kg)

41.73

Included Battery Pack Weight (lbs.) 

92

Included Mounting Accessory Description

3 sets of adjustable 4 post rackmount installation rails included

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )

Maximum Device Depth (cm)

66.04

Maximum Device Depth (in.) 

26

Maximum Device Depth (mm)

660

Minimum Required Rack Depth (cm)

83.82 

Minimum Required Rack Depth
(inches) 

33

Optional Mounting Accessory Notes

3 sets of  2POSTRMKITHD  required for 2 post rackmount installation of separate power module, transformer and battery pack

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

660

Primary UPS Height (mm)

132

Primary UPS Width (mm)

445

Rack Height

7U

Shipping Dimensions (hwd / cm)

78.74 x 68.58 x 83.82

Shipping Dimensions (hwd / in.)

31.00 x 27.00 x 33.00 

Shipping Weight (kg)

130.63

Shipping Weight (lbs.)

288.00

Stepdown Transformer Depth (mm)

533

Stepdown Transformer Dimensions (hwd / cm)

8.89 x 44.45 x 53.34

Stepdown Transformer Dimensions (hwd / in.) 

3.5 x 17.5 x 21

Stepdown Transformer Height (mm)

89

Stepdown Transformer Weight (kg) 

25.85

Stepdown Transformer Weight (lbs.)

57

Stepdown Transformer Width (mm)

445

Unit Dimension Details

Includes 3U UPS/power module, 2U stepdown transformer and 2U external battery pack

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

13.21 x 44.45 x 66.04

UPS Power Module Dimensions (hwd, in.)

5.2 x 17.5 x 26

UPS Power Module Weight (kg)

19.05

UPS Power Module Weight (lbs.)

42 

 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

1327

Battery Mode BTU / Hr. (Full Load)

1327

AC Mode Efficiency Rating (100% Load)

90%

AC Economy Mode Efficiency Rating (100% Load)

94%


Communications:

Network Management Cards

SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD

Network Monitoring Port Description

RS232 and contact closure communications are located on two separate DB9 ports

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

DB9 cable included

Communications Interface

DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 208V AC
Output (VA) 5000VA
Output Voltage 208V AC
PDU Total Outlets No