Description
Details
Love Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline UPS 5kVA 3.8kW, RM, 4U, 30A, 208/240V, Split phase, New Batteries, Refurbished UPS
Condition: New batteries, refurbished UPS
Part Number: SU5000RT4U
Maximum output: 3800W / 5000VA
Typical backup time at half load: 14 minutes (1900 Watts)
Typical backup time at full load: 6 minutes (3800 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 5000VA 3800W RM 4U 208/240V SU5000RT4U User's Manual
SU5000RT4U - Tripp Lite SmartOnline 5000VA Specifications:
Input:
Rated input current (Maximum Load) |
21A |
||
Nominal Input Voltage(s) Supported |
120/208V (Split phase L1,L2,N,G); 120/240V (Split phase L1,L2,N,G) |
||
UPS Input Connection Type |
|
||
UPS Input Connection Description |
4 wire split-phase input (L1, L2, N, G) |
||
UPS Input Cord Length (ft.) |
10 |
||
UPS Input Cord Length (m) |
3.1 |
||
Recommended Electrical Service |
30A 208/120V Split Phase |
||
Input Phase |
Single-Phase |
||
Input Cord Length (m) |
3 |
Output:
Output Volt Amp Capacity (VA) |
5000 |
||||||
Output kVA Capacity (kVA) |
5 |
||||||
Output Watt Capacity (Watts) |
3800 |
||||||
Output kW Capacity (kW) |
3.8 |
||||||
Power Factor |
0.8 |
||||||
Crest Factor |
3:1 |
||||||
Nominal Voltage Details |
240/120V or 208/120V split phase output |
||||||
Frequency Compatibility |
60 Hz |
||||||
Output Voltage Regulation (Line Mode) |
+/- 3% |
||||||
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||||||
Output Voltage Regulation (Battery Mode) |
+/- 3% |
||||||
Output Circuit Breakers |
20A branch rated breakers (x4) protect 2 5-15/20R outlets each, 20A double pole breakers (x2) protect one L6-20R each, L6-30R outlets are unbreakered |
||||||
Output AC Waveform (AC Mode) |
Pure Sine wave |
||||||
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||||
Output Capacity Details |
Supports up to 105% load continuously in double conversion mode, 106 to 125% for 3 minutes, 126 to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support equipment directly from mains power; Double conversion mode is automatically restored as the overload is cleared |
||||||
Nominal Output Voltage(s) Supported |
120V; 208V; 240V |
||||||
Output Receptacles |
|
||||||
Individually Controllable Load Banks |
No |
Battery:
Full Load Runtime (min.) |
6 min. (3800w) |
Half Load Runtime (min.) |
14 min. (1900w) |
Expandable Battery Runtime |
Supports extended runtime with optional external battery packs |
External Battery Pack Compatibility |
|
DC System Voltage (VDC) |
192 |
Battery Recharge Rate (Included Batteries) |
Less than 6 hours from 10% to 80% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge |
RBC9-192 |
Battery Access |
Front panel battery access door |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Expandable Runtime |
Yes |
Voltage Regulation:
Voltage Regulation Description |
+/-3% output voltage regulation in online, double-conversion mode |
Overvoltage Correction |
Corrects overvoltages to 140 (measured L1-N : L2-N) |
Undervoltage Correction |
Corrects undervoltages to 65 (measured L1-N : L2-N) |
User Interface, Alerts & Controls:
Front Panel LCD Display |
Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats |
Switches |
Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads. Battery Charge level switch allows the charger output to be adjusted to a higher charge rate when additional battery packs are added. |
Alarm Cancel Operation |
Alarm cancel switch |
Audible Alarm |
Unique audible alarms for all major UPS, environmental and power conditions (see manual) |
LED Indicators |
6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD |
Surge / Noise Suppression:
UPS AC Suppression Joule Rating |
1810 |
UPS AC Suppression Response Time |
Instantaneous |
EMI / RFI AC Noise Suppression |
Yes |
Physical:
Cooling Method |
Fan
|
Included Mounting Accessory Description |
Not included |
Installation Form Factors Supported |
4 post 19 inch rackmount |
Installation Form Factors Supported with Optional Accessories |
2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND ) |
Maximum Device Depth (cm) |
77.72 |
Maximum Device Depth (in.) |
30.6 |
Maximum Device Depth (mm) |
777 |
Minimum Required Rack Depth with |
87 |
Minimum Required Rack Depth with External Battery Pack (in.) |
34.2 |
Minimum Required Rack Depth |
87 |
Minimum Required Rack Depth |
34.2 |
Primary Form Factor |
Rackmount |
Primary UPS Depth (mm) |
777 |
Primary UPS Height (mm) |
175 |
Primary UPS Width (mm) |
445 |
Rack Height |
4U |
Shipping Dimensions (hwd / cm) |
35.56 x 60.96 x 91.44 |
Shipping Dimensions (hwd / in.) |
14.00 x 24.00 x 36.00 |
Shipping Weight (kg) |
94.35 |
Shipping Weight (lbs.) |
208.00 |
Unit Dimension Details |
MINIMUM REQUIRED RACK DEPTH specifications refer to the internal FRONT RAIL to REAR DOOR dimension a compatible rack enclosure is required to accommodate for the UPS configuration described; All minimum required rack depth figures include any additional distance required to accommodate connected equipment plugs |
UPS Housing Material |
Steel |
UPS Power Module Dimensions (hwd, cm) |
17.50 x 44.45 x 77.72 |
UPS Power Module Dimensions (hwd, in.) |
6.89 x 17.5 x 30.6 |
UPS Power Module Weight (kg) |
67.86 |
UPS Power Module Weight (lbs.) |
149.6 |
Environmental:
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
1441 |
AC Economy Mode BTU / Hr. (Full Load) |
827 |
Battery Mode BTU / Hr. (Full Load) |
1283 |
AC Economy Mode Efficiency Rating (100% Load) |
94% |
Operating Elevation (ft.) |
0-3000m (0 to 10,000 ft.) |
Audible Noise |
60 dBA at front side 1 meter |
Operating Elevation (m) |
0-3000 m |
Communications:
Optional Network Management Cards (not included) |
SNMPWEBCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD |
Network Monitoring Port Description |
RS232 and contact closure communications are supported on one DB9 port |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert |
Communications Cable |
USB and DB9 cabling included |
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Communications Interface |
Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
Additional Info
Additional Info
Manufacturer | Tripp Lite |
---|---|
Form Factor | Rackmount |
Waveform in Battery Mode | Pure Sinewave |
Input Voltage | 208V AC, 240V AC |
Output (VA) | 5000VA |
Output Voltage | 120V AC, 208V AC, 240V AC |
PDU Total Outlets | No |