Call toll free: 1-866-311-1945 | sales@excessups.ca
Your Region:

Tripp Lite SmartOnline 6000VA 4200W RM 6U 208V/240V SU6000RT3UHV - Refurbished

Tripp Lite SmartOnline 6000VA 4200W RM 6U
Model: SU6000RT3UHV
Input: Hardwire (200V/240V - 60A)
Output: Hardwire
Double Conversion Online UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
CAD $2,199.99
Availability: In stock

Description

Details

Love Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 6000VA 4200W, RM, 6U, 60A, 208V/240V, New Batteries, Refurbished UPS
Condition:
New batteries, refurbished UPS
Part Number:
SU6000RT3UHV

Maximum output: 4200W / 6000VA
Typical backup time
at half load: 20 minutes (2100 Watts)
Typical backup time
at full load: 8 minutes (4200 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 6000VA 4200W RM 6U 208V/240V SU6000RT3UHV Manual


SU6000RT3UHV - Tripp Lite SmartOnline 6000VA Specifications:

Input:

Rated input current (Maximum Load)

30A

Nominal Input Voltage(s) Supported

200V AC; 208V AC; 220V AC; 230V AC; 240V AC

Nominal Input Voltage Description

Factory configured to 208V

UPS Input Connection Type

Hardwire

UPS Input Connection Description

Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring; Optional SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord

Input Circuit Breakers

40A double-pole

Recommended Electrical Service

30A 208/220/230/240V

Input Phase

Single-Phase


Output:

Output Volt Amp Capacity (VA)

6000

Output kVA Capacity (kVA)

6

Output Watt Capacity (Watts)

4200

Output kW Capacity (kW)

4.2

Power Factor

0,7

Crest Factor

3:1

Nominal Voltage Details

Voltage selection via front panel LCD interface

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details 

Output frequency matches input nominal on startup

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Output Receptacle Backplate Options

Optional SUPDM11 backplate adds 2 L6-30R outlets and L6-30P input cord

Output Circuit Breakers

40A double-pole

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Output Capacity Details 

Supports up to 102% load continuously in double conversion mode, 102 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 90% or less

Nominal Output Voltage(s) Supported

200V; 208V; 220V; 230V; 240V

Output Receptacles

 Hardwire

 

Individually Controllable Load Banks

No


Battery:

Full Load Runtime (min.)

8 min. (4200w)

Half Load Runtime (min.)

20 min. (2100w)

Expandable Battery Runtime

Includes one non-expandable BP240V7RT3U (limit 1) external battery pack. No additional BP240V7RT3U external battery packs can be connected to the host UPS, beyond the one included with the SU6000RT3UHV UPS bundle. All additional battery packs connected beyond the included BP240V7RT3U, must be  BP240V10RT3U , BP240V557C-1PH,  BP240V787C-1PH , BP240V1037C-1PH or BP240V1407C-1PH

External Battery Pack Compatibility

BP240V10RT3U ; BP240V557C-1PH;  BP240V787C-1PH ; BP240V1037C1PH; BP240V1407C-1PH

DC System Voltage (VDC)

240

Battery Recharge Rate (Included Batteries) 

Less than 6 hours from 10% to 80% (typical, full load discharge)

Battery Replacement Description

Hot-swappable, user replaceable batteries

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

2% output voltage regulation during overvoltages to 276

Undervoltage Correction

2% output voltage regulation during undervoltages to 156


User Interface, Alerts & Controls:

Front Panel LCD Display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions

Alarm Cancel Operation

Alarm cancel switch

Audible Alarm

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options


Surge / Noise Suppression:

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Battery Pack Dimensions (hwd / in.)

5.2 x 17.5 x 25

Included Battery Pack Weight (kg)

61.92

Included Battery Pack Weight (lbs.)

136.5

Included Mounting Accessory Description

2 sets of adjustable 4 post rack rails included (for UPS and battery pack components); 2-9USTAND tower kit
included (supports up to 9U in tower format)

Installation Form Factors Supported
with Optional Accessories

2 post rackmount ( 2POSTRMKITHD )

Maximum Device Depth (cm)

66.04

Maximum Device Depth (in.)

26

Maximum Device Depth (mm)

660 

Minimum Required Rack Depth (cm)

83.82

Minimum Required Rack Depth
(inches)

33

Optional Mounting Accessory Notes

2 sets of  2POSTRMKITWM  required for 2 post rackmount installation of separate power module and battery pack

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

660

Primary UPS Height (mm)

132

Primary UPS Width (mm)

445

Rack Height

6U

Shipping Dimensions (hwd / cm)

62.23 x 60.96 x 88.90

Shipping Dimensions (hwd / in.)

24.50 x 24.00 x 35.00 

Shipping Weight (kg)

146.51

Shipping Weight (lbs.)

323.00

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

13.21 x 44.45 x 66.04

UPS Power Module Dimensions (hwd, in.)

5.2 x 17.5 x 26

UPS Power Module Weight (kg)

19.87

UPS Power Module Weight (lbs.)

43.8 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

1418

AC Economy Mode BTU / Hr. (Full Load) 

640

Battery Mode BTU / Hr. (Full Load)

1593

AC Mode Efficiency Rating (100% Load)

91%

AC Economy Mode Efficiency Rating (100% Load)

94%

Operating Elevation (ft.)

0-3000m (0 to 10,000 ft.)

Audible Noise

60 dBA at front side 1 meter

Operating Elevation (m)

0 - 3000 m


Communications:

Network Management Cards

SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD

Network Monitoring Port Description

RS232 and contact closure communications are located on two separate DB9 ports

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at
http://www.tripplite.com/poweralert

Communications Cable

DB9 cable included 

WatchDog Compatibility

Yes

Communications Interface

DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 240V AC
Output (VA) 6000VA
Output Voltage 208V AC, 240V AC
PDU Total Outlets No

You may also be interested in