Call toll free: 1-866-311-1945 | sales@excessups.ca
Your Region:

Tripp Lite SmartOnline 3000VA 2400W RM 3U 120V SU3000RTXR3U - Refurbished

Tripp Lite SmartOnline 3000VA 2400W RM 3U
Model: SU3000RTXR3U
Input: NEMA L5-30P (120V - 30A)
Output: (4) NEMA 5-15R, (4) NEMA 5-15/20R, (1) NEMA L5-30R
Online Double Conversion UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
  • 1 Year
    Included
  • 2 Year
    +CAD $143.00
  • 3 Year `
    +CAD $250.25

* Required Fields

CAD $714.99
Availability: In stock

Description

Details

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline 3000VA 2400W, RM, 3U, 120V
Condition:
New batteries, refurbished UPS
Part Number:
SU3000RTXR3U

Maximum output: 2400W / 3000VA
Typical backup time
at half load: 30 minutes (1200 Watts)
Typical backup time
at full load: 12 minutes (2400 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 3000VA 2400W RM 120V SU3000RTXR3U Manual


SU3000RTXR3U - Tripp Lite SmartOnline 3000VA Specifications:

Input:

Rated input current (Maximum Load)

24A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

NEMA L5-30P

Input Circuit Breakers

40A

UPS Input Cord Length (ft.)

10

Recommended Electrical Service

30A 120V

Input Phase

Single-Phase


Output:

Output Volt Amp Capacity (VA)

3000

Output Capacity (kVA)

3

Output Watt Capacity (Watts)

2400

Output kW Capacity (kW)

2.4

Output Capacity Details

OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits)

Power Factor

0.8

Crest Factor

3:1

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Load Management Receptacles

Two switchable four-outlet load banks, (bank 1 - four 5-15/20R, bank 2 - four 5-15R outlets)

Output Circuit Breakers

15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

120V

Output Receptacles

(4) NEMA 5-15R

(4) NEMA 5-15/20R

(1) NEMA L5-30R

Individually Controllable Load Banks

Yes


Battery:

Battery Type

Valve Regulated Lead Acid (VRLA)

Full Load Runtime (min.)

12 min. (2400w)

Half Load Runtime (min.)

30 min. (1200w)

Expandable Battery Runtime

Supports extended runtime with optional external battery packs

Expandable Runtime

Yes

External Battery Pack Compatibility

BP72V15-2U  (limit 1);  BP72V28RT-3U  (multi-pack compatible);  BP72V18-2US  (multi-pack compatible)

DC System Voltage (VDC)

72

Battery Recharge Rate (Included Batteries)

Less than 6 hours from 10% to 80% (typical, full load discharge)

Battery Access

Front panel battery access door

Internal UPS Replacement Battery Cartridge

RBC96-3U  (quantity 2)

Battery Replacement Description

Hot-swappable, user replaceable batteries


Voltage Regulation:

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

2% output voltage regulation during overvoltages to 150

Undervoltage Correction

2% output voltage regulation during undervoltages to 80

Severe Undervoltage Correction

2% output voltage regulation during undervoltages to 65 (under 70% load only)


User Interface, Alerts & Controls:

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch

Audible Alarm

Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions

LED Indicators

14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

480

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet

EMI / RFI AC Noise Suppression

Yes


Physical:

Primary Form Factor

Rackmount

Cooling Method

Fan

Included Mounting Accessory Description

Includes 4 post rackmount installation accessories

Installation Form Factors Supported with Included Accessories

4 post 19 inch rackmount

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )

Minimum Required Rack Depth with External Battery Pack (cm)

77

Minimum Required Rack Depth with External Battery Pack (in.)

30.25

Minimum Required Rack Depth without External Battery Pack (cm)

80

Minimum Required Rack Depth without External Battery Pack (in.)

31.5

Primary UPS Depth (mm)

660

Primary UPS Height (mm)

132

Primary UPS Width (mm)

452

Rack Height

3U

Shipping Dimensions (hwd / in.)

11.50 x 23.00 x 33.00

Shipping Weight (lbs.)

150.00

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, in.)

5.2 x 17.8 x 26

UPS Power Module Weight (kg)

50.48

UPS Power Module Weight (lbs.)

111.3


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

1117

AC Economy Mode BTU / Hr. (Full Load)

253

Battery Mode BTU / Hr. (Full Load)

1224

AC Mode Efficiency Rating (100% Load)

88%

AC Economy Mode Efficiency Rating (100% Load)

97%


Communications:

Network Management Cards

SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications; Economy-mode setting option is available using PowerAlert software and DB9 Serial cable connection OR via select Network Management Card options

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network Management Card Description

Network management card optional

Communications Interface

Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 3000VA
Output Voltage 120V AC
PDU Total Outlets No

You may also be interested in