Description
Details
Love Manufacturer: Tripp Lite
Model: Tripp Lite SmartOnline UPS 3000VA 2400W, RM, 3U, 30A, 120V, New Batteries, Refurbished UPS
Condition: New batteries, refurbished UPS
Part Number: SU3000RTXL3U
Maximum output: 2400W / 3000VA
Typical backup time at half load: 14 minutes (1200 Watts)
Typical backup time at full load: 5 minutes (2400 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 3000VA 2400W RM 3U 120V SU3000RTXL3U User's Manual
SU3000RTXL3U - Tripp Lite SmartOnline 3000VA Specifications:
Input:
Rated input current (Maximum Load) |
24A |
||
Nominal Input Voltage(s) Supported |
110V AC; 120V AC |
||
UPS Input Connection Type |
|
||
Input Circuit Breakers |
40A |
||
UPS Input Cord Length (ft.) |
10 |
||
UPS Input Cord Length (m) |
3.1 |
||
Recommended Electrical Service |
30A 120V |
||
Input Phase |
Single-Phase |
Output:
Output Volt Amp Capacity (VA) |
3000 |
||||||
Output kVA Capacity (kVA) |
3 |
||||||
Output Watt Capacity (Watts) |
2400 |
||||||
Output kW Capacity (kW) |
2.4 |
||||||
Power Factor |
0.8 |
||||||
Crest Factor |
3:1 |
||||||
Nominal Voltage Details |
120V default |
||||||
Frequency Compatibility |
50 / 60 Hz |
||||||
Frequency Compatibility Details |
Output frequency matches input nominal on startup, defaults to 60 Hz on cold-start |
||||||
Output Voltage Regulation (Line Mode) |
+/- 2% |
||||||
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
||||||
Output Voltage Regulation (Battery Mode) |
+/- 2% |
||||||
Load Management Receptacles |
Two switchable four-outlet load banks, (bank 1 - four 5-15/20R, bank 2 - four 5-15R outlets) |
||||||
Output Circuit Breakers |
15A branch rated (x2) - each breaker protects 4 outlets, L5-30R is unbreakered |
||||||
Output AC Waveform (AC Mode) |
Pure Sine wave |
||||||
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||||
Output Capacity Details |
OVERLOAD CAPACITY: Supports inverter operation up to 105% load continuously, 125% load for 3 minutes; 150% load for 30 seconds and >150% load for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN bypass limits) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits) |
||||||
Nominal Output Voltage(s) Supported |
110V; 120V |
||||||
Output Receptacles |
|
||||||
Individually Controllable Load Banks |
Yes |
Battery:
Full Load Runtime (min.) |
5 min. (2400w) |
Half Load Runtime (min.) |
14 min. (1200w) |
Expandable Battery Runtime |
Supports extended runtime with optional external battery packs |
External Battery Pack Compatibility |
BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible) |
DC System Voltage (VDC) |
72 |
Battery Recharge Rate (Included Batteries) |
Less than 6 hours from 10% to 80% (typical, full load discharge) |
Internal UPS Replacement Battery Cartridge |
RBC96-3U (quantity 1) |
Battery Access |
Front panel battery access door |
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Expandable Runtime |
Yes |
Voltage Regulation:
Voltage Regulation Description |
Online, double-conversion power conditioning |
Overvoltage Correction |
2% output voltage regulation during overvoltages to 150 |
Undervoltage Correction |
2% output voltage regulation during undervoltages to 80 |
Severe Undervoltage Correction |
2% output voltage regulation during undervoltages to 65 (under 70% load only) |
User Interface, Alerts & Controls:
Switches |
2 switches control off/on power status and alarm-cancel/self-test operation |
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch |
Audible Alarm |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown |
LED Indicators |
14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery |
Surge / Noise Suppression:
UPS AC Suppression Joule Rating |
510 |
UPS AC Suppression Response Time |
Instantaneous |
UPS Dataline Suppression |
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet |
EMI / RFI AC Noise Suppression |
Yes |
Physical:
Cooling Method |
Fan
|
Included Mounting Accessory Description |
Includes 4 post rackmount installation accessories |
Installation Form Factors Supported with Optional Accessories |
2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND ) |
Minimum Required Rack Depth with |
81 |
Minimum Required Rack Depth with |
32 |
Minimum Required Rack Depth without External Battery Pack (cm) |
79 |
Minimum Required Rack Depth |
31 |
Primary Form Factor |
Rackmount |
Primary UPS Depth (mm) |
660 |
Primary UPS Height (mm) |
132 |
Primary UPS Width (mm) |
452 |
Rack Height |
3U |
Shipping Dimensions (hwd / cm) |
25.40 x 58.42 x 83.82 |
Shipping Dimensions (hwd / in.) |
10.00 x 23.00 x 33.00 |
Shipping Weight (kg) |
50.80 |
Shipping Weight (lbs.) |
112.00 |
UPS Housing Material |
Steel |
UPS Power Module Dimensions (hwd, cm) |
13.21 x 45.21 x 66.04 |
UPS Power Module Dimensions (hwd, in.) |
5.2 x 17.8 x 26 |
UPS Power Module Weight (kg) |
33.48 |
UPS Power Module Weight (lbs.) |
73.8 |
Environmental:
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC Mode BTU / Hr. (Full Load) |
1117 |
AC Economy Mode BTU / Hr. (Full Load) |
523 |
Battery Mode BTU / Hr. (Full Load) |
1224 |
AC Mode Efficiency Rating (100% Load) |
91% |
AC Economy Mode Efficiency Rating (100% Load) |
94% |
Communications:
Network Management Cards |
SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD |
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure |
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralertt |
Communications Cable |
USB and DB9 cabling included |
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
Communications Interface |
Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
Additional Info
Additional Info
Manufacturer | Tripp Lite |
---|---|
Form Factor | Rackmount |
Waveform in Battery Mode | Pure Sinewave |
Input Voltage | 120V AC |
Output (VA) | 3000VA |
Output Voltage | 120V AC |
PDU Total Outlets | No |