Description
Details
Manufacturer: Tripp Lite
Model: Refurbished Tripp Lite SmartPro UPS 2200VA LCD 120V with New Batteries
Part Number: SMART2200RM2U
Warranty: 1 Year Full Replacement Warranty, additional warranty available
Maximum output: 1920W / 2200VA
Typical backup timeat half load: 19.0 minutes (960Watts)
Typical backup time at full load: 4.5 minutes (1920Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartPro UPS 2200VA LCD SMART2200RM2U Manual
SMART2200RM2U - Tripp Lite SmartPro UPS 2200VA LCD Specifications:
Output:
OUTPUT |
|
Output Volt Amp Capacity (VA) |
2200 |
Output kVA capacity (kVA) |
2.2 |
Output Watt Capacity (watts) |
1920 |
Output kW capacity |
1.92 |
Output power factor |
0.87 |
Nominal Output Voltage(s) Supported |
120V |
Frequency compatibility |
60 Hz |
Output voltage regulation (line mode) |
-14%, +6% |
Output voltage regulation (Battery mode) |
+/- 5% |
Built-in UPS output receptacles |
4 5-15R outlet(s); 4 5-15/20R outlet(s) |
Built-in controllable switched load banks |
Two switchable single-outlet load banks |
Output AC waveform (AC mode) |
Pure Sine wave |
Output AC waveform (battery mode) |
Pure Sine wave |
INPUT |
|
Rated input current (at maximum load) |
16A (120V) |
Nominal Input Voltage(s) Supported |
120V AC |
UPS input connection type |
5-20P |
Input circuit breaker |
20A |
UPS Input cord length (ft.) |
10 |
UPS Input cord length (m) |
3 |
Recommended Electrical Service |
20A 120V |
Phase |
Single-Phase |
BATTERY |
|
Full load runtime (minutes) |
4.5 min. (1920w) |
Half load runtime (minutes) |
12 min. (960w) |
DC system voltage (VDC) |
48 |
Battery recharge rate (included batteries) |
Less than 4.5 hours from 10% to 90% |
Replacement battery cartridge (internal UPS battery replacement) |
RBC94-2U |
Battery Access |
Front panel battery access door |
Battery replacement description |
Hot-swappable, user replaceable batteries |
VOLTAGE REGULATION |
|
Voltage regulation description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 |
Overvoltage correction |
Input voltages between 127 and 145 are reduced by 12% |
Undervoltage correction |
Input voltages between 108 and 96 are boosted by 12% |
Severe undervoltage correction |
Input voltages between 83 and 95 are boosted by 24% |
LEDS ALARMS & SWITCHES |
|
Front panel LCD display |
Front panel LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) |
Alarms |
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions |
Alarm cancel operation |
Power-fail alarm can be temporarily silenced using alarm-cancel switch; silent mode alarm configuration option available |
Switches |
3 pushbutton switches control OFF / ON power status, MODE selection and MUTE / ENTER control functions |
SURGE / NOISE SUPPRESSION |
|
UPS AC suppression joule rating |
570 |
UPS AC suppression response time |
Instantaneous |
EMI / RFI AC noise suppression |
Yes |
PHYSICAL |
|
Installation form factors supported with included accessories |
4 post 19 inch rackmount (mounting rail kit included) |
Installation form factors supported with optional accessories |
2 post rackmount (2POSTRMKITWM); Wallmount (2POSTRMKITWM); Tower (2-9USTAND) |
Primary form factor |
Rackmount |
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) |
3.5 x 17.5 x 19.5 |
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) |
8.9 x 44.4 x 49.4 |
Rack Height |
2U |
Secondary form factor |
Tower (requires 2-9USTAND) |
UPS / Power Module weight (lbs) |
57.6 |
UPS / Power Module weight (kg) |
26.1 |
UPS Shipping dimensions (height x width x depth / inches) |
7.9 x 21.7 x 24.2 |
UPS Shipping dimensions (height x width x depth / cm) |
20.1 x 55.1 x 61.5 |
Shipping weight (lbs) |
57.6 |
Shipping weight (kg) |
26.2 |
Cooling method |
Fan |
UPS housing material |
Steel |
ENVIRONMENTAL |
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
Relative Humidity |
0 to 95%, non-condensing |
AC mode BTU / hr. (full load) |
306 |
COMMUNICATIONS |
|
Communications interface |
USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface |
Network monitoring port description |
Supports detailed monitoring of UPS and site power conditions |
Communications cable |
USB, DB9 and EPO cabling (NOT INCLUDED) |
WatchDog compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
LINE / BATTERY TRANSFER |
|
Transfer time |
5 milliseconds (AC to battery mode), 1 millisecond (Battery to AC mode) |
Low voltage transfer to battery power (setpoint) |
83 |
High voltage transfer to battery power (setpoint) |
145 |
SPECIAL FEATURES |
|
Grounding lug |
Back panel grounding lug |
Cold Start (startup in battery mode during a power failure) |
Cold-start operation supported |
High availability UPS features |
Hot swappable batteries |
Green & high efficiency features |
Greater than 95% efficiency - GREEN UPS; Individually controllable load banks |
CERTIFICATIONS |
|
UPS Certifications |
Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI) |
Additional Info
Additional Info
Manufacturer | Tripp Lite |
---|---|
Form Factor | Rackmount |
Waveform in Battery Mode | Pure Sinewave |
Input Voltage | No |
Output (VA) | 2200VA |
Output Voltage | No |
PDU Total Outlets | N/A |