Call toll free: 1-866-311-1945 | sales@excessups.ca
Your Region:

Tripp Lite SmartOnline 5000VA 3.8kW RM 4U 208/240V & 120V Split Phase SU5000RT4U - Refurbished

Tripp Lite SmartOnline 5000VA 3800W RM 4U 208V/240V Split Phase
Model: SU5000RT4U
Input: NEMA L14-30P (240V - 30A)
Output: (8) 5-15/20R, (2) L6-20R, (2) L6-30R
Double Conversion Online UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
CAD $2,199.99
Availability: In stock

Description

Details

Love Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 5kVA 3.8kW, RM, 4U, 30A, 208/240V, Split phase, New Batteries, Refurbished UPS
Condition:
New batteries, refurbished UPS
Part Number:
SU5000RT4U

Maximum output: 3800W / 5000VA
Typical backup time
at half load: 14 minutes (1900 Watts)
Typical backup time
at full load: 6 minutes (3800 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 5000VA 3800W RM 4U 208/240V SU5000RT4U User's Manual


SU5000RT4U - Tripp Lite SmartOnline 5000VA Specifications:

Input:

Rated input current (Maximum Load)

21A

Nominal Input Voltage(s) Supported

120/208V (Split phase L1,L2,N,G); 120/240V (Split phase L1,L2,N,G)

UPS Input Connection Type

L14-30P

UPS Input Connection Description

4 wire split-phase input (L1, L2, N, G)

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Recommended Electrical Service

30A 208/120V Split Phase

Input Phase

Single-Phase

Input Cord Length (m)

3

Output:

Output Volt Amp Capacity (VA)

5000

Output kVA Capacity (kVA)

5

Output Watt Capacity (Watts)

3800

Output kW Capacity (kW)

3.8

Power Factor

0.8

Crest Factor

3:1

Nominal Voltage Details

240/120V or 208/120V split phase output

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode)

+/- 3%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 3%

Output Circuit Breakers

20A branch rated breakers (x4) protect 2 5-15/20R outlets each, 20A double pole breakers (x2) protect one L6-20R each, L6-30R outlets are unbreakered

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Output Capacity Details

Supports up to 105% load continuously in double conversion mode, 106 to 125% for 3 minutes, 126 to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support equipment directly from mains power; Double conversion mode is automatically restored as the overload is cleared

Nominal Output Voltage(s) Supported

120V; 208V; 240V

Output Receptacles

(8) NEMA 5-15/20R

(2) NEMA L6-20R

(2) NEMA L6-30R

Individually Controllable Load Banks

No


Battery:

Full Load Runtime (min.)

6 min. (3800w)

Half Load Runtime (min.)

14 min. (1900w)

Expandable Battery Runtime

Supports extended runtime with optional external battery packs

External Battery Pack Compatibility

BP192V12-3U ;  BP192V5RT2U  (limit 1);  BP192V787C-1PH

DC System Voltage (VDC)

192

Battery Recharge Rate (Included Batteries) 

Less than 6 hours from 10% to 80% (typical, full load discharge)

Internal UPS Replacement Battery Cartridge

RBC9-192

Battery Access

Front panel battery access door

Battery Replacement Description

Hot-swappable, user replaceable batteries

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

+/-3% output voltage regulation in online, double-conversion mode

Overvoltage Correction

Corrects overvoltages to 140 (measured L1-N : L2-N)

Undervoltage Correction

Corrects undervoltages to 65 (measured L1-N : L2-N)


User Interface, Alerts & Controls:

Front Panel LCD Display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats

Switches

Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads. Battery Charge level switch allows the charger output to be adjusted to a higher charge rate when additional battery packs are added.

Alarm Cancel Operation

Alarm cancel switch

Audible Alarm

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD
screen offers additional information and control options


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

1810

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Mounting Accessory Description

Not included

Installation Form Factors Supported

4 post 19 inch rackmount

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )

Maximum Device Depth (cm)

77.72 

Maximum Device Depth (in.)

30.6

Maximum Device Depth (mm)

777

Minimum Required Rack Depth with
External Battery Pack (cm)

87

Minimum Required Rack Depth with External Battery Pack (in.)

34.2

Minimum Required Rack Depth
without External Battery Pack (cm)

87

Minimum Required Rack Depth
without External Battery Pack (in.)

34.2

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

777

Primary UPS Height (mm)

175

Primary UPS Width (mm)

445

Rack Height

4U

Shipping Dimensions (hwd / cm)

35.56 x 60.96 x 91.44

Shipping Dimensions (hwd / in.)

14.00 x 24.00 x 36.00 

Shipping Weight (kg)

94.35

Shipping Weight (lbs.)

208.00

Unit Dimension Details

MINIMUM REQUIRED RACK DEPTH specifications refer to the internal FRONT RAIL to REAR DOOR dimension a compatible rack enclosure is required to accommodate for the UPS configuration described; All minimum required rack depth figures include any additional distance required to accommodate connected equipment plugs

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

17.50 x 44.45 x 77.72

UPS Power Module Dimensions (hwd, in.)

6.89 x 17.5 x 30.6

UPS Power Module Weight (kg)

67.86

UPS Power Module Weight (lbs.)

149.6 

 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

1441

AC Economy Mode BTU / Hr. (Full Load)

827

Battery Mode BTU / Hr. (Full Load)

1283

AC Economy Mode Efficiency Rating (100% Load)

94%

Operating Elevation (ft.)

0-3000m (0 to 10,000 ft.)

Audible Noise

60 dBA at front side 1 meter

Operating Elevation (m)

0-3000 m


Communications:

Optional Network Management Cards (not included)

SNMPWEBCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD

Network Monitoring Port Description

RS232 and contact closure communications are supported on one DB9 port

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Communications Interface

Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 208V AC, 240V AC
Output (VA) 5000VA
Output Voltage 120V AC, 208V AC, 240V AC
PDU Total Outlets No

You may also be interested in

Related Products