Tripp Lite SmartPro 1.5kVa 1500VA 900W SMART1500SLT - Refurbished

Tripp Lite SmartPro UPS 1.5kVa 900W Tower UPS
New batteries, Refurbished UPS
Model: SMART1500SLT
Input: NEMA 5-15P (120V 15A)
Output: (8) NEMA 5-15R
- 120V 15A
Line-Interactive UPS - Sinewave Output
1 Year Warranty Included

Availability: In stock

Regular Price: CAD $199.99

Now only: CAD $149.99

Shipping Info
  • This item is in stock and ships within 1 business day
  • We will gladly accept returns for any reason within 30 days of receipt of delivery
  • Continental USA & Canada

Description

Details

Manufacturer: Tripp Lite
Model: Refurbished Tripp Lite SmartPro 1.5kVA 1
500VA 900W 120V Line-Interactive UPS, AVR, Tower, USB, 8 Outlets
Condition: New batteries, refurbished UPS
Part Number: SMART1500SLT
Maximum output: 900W / 1500VA
Typical backup time
at half load: 20 minutes (450W)
Typical backup time
at full load: 8 minutes (900Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SMART1500SLT Owner's Manual

SMART1500SLT - Tripp Lite SmartPro 1.5KVA 1500VA 900W UPS Specifications:

OUTPUT

Output Volt Amp Capacity (VA)

1500

Output kVA Capacity (kVA)

1.5

Output Watt Capacity (Watts)

900W

Nominal Output Voltage(s) Supported

120V

Nominal Voltage Details

120V default

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Automatic Frequency Selection

Output Voltage Regulation (Line Mode)

-10%, +6%

Output Voltage Regulation (Economy Line Mode)

+/- 5%

Output Receptacles

(8) 5-15R

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

INPUT

Rated input current (Maximum Load)

12A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

5-15P

Input Circuit Breakers

20A

UPS Input Cord Length (ft.)

6

UPS Input Cord Length (m)

1.8

Recommended Electrical Service

15A 120V

Input Phase

Single-Phase

BATTERY

Full Load Runtime (min.)

8 min. (900W)

Half Load Runtime (min.)

20 min. (450W)

Internal UPS Replacement Battery Cartridge

(1) RBC36-SLT

VOLTAGE REGULATION

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation an input voltage range of 83 to 121

Overvoltage Correction

Voltage reduction of 12% applies when input is 127 to 145 (120v), 116 to 133 (110v), 111 to 121 (100v)

Undervoltage Correction

Voltage boost of 14% applies when input is 95 to 108 (120v), 87 to 99 (110v), 83 to 90 (100v)

USER INTERFACE, ALERTS & CONTROLS

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support nominal voltage selection

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch

Audible Alarm

Audible alarm indicates power failure and overload conditions

LED Indicators

Status LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level

Site Wiring Fault

Rear panel site wiring fault LED

SURGE / NOISE SUPPRESSION

UPS AC Suppression Joule Rating

690

UPS AC Suppression Response Time

Instantaneous

UPS Dataline Suppression

1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet

EMI / RFI AC Noise Suppression

Yes

PHYSICAL

Primary Form Factor

Tower

Shipping Weight (lbs)

45lbs

Cooling Method

Fan

UPS Housing Material

Steel

Primary UPS Height (mm)

259mm

Primary UPS Width (mm)

173mm

Primary UPS Depth (mm)

335

ENVIRONMENTAL

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

148

Battery Mode BTU / Hr. (Full Load)

500

AC Economy Mode Efficiency Rating (100% Load)

95%

COMMUNICATIONS

Communications Interface

USB; DB9 Serial; Slot for SNMP/Web interface

Compatible network management cards (NOT INCLUDED)

SNMPWEBCARD; WEBCARDLX;  RELAYIOCARD

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB and DB9 Supported, cabling NOT INCLUDED

LINE / BATTERY TRANSFER

Transfer Time

4ms (AC to Battery), 6ms (Battery to AC mode)

Low Voltage Transfer to Battery Power (Setpoint)

95V (120V), 87V (110V), 83V (100V)

High Voltage Transfer to Battery Power (Setpoint)

145V (120V), 133V (110V), 121V (100V)

SPECIAL FEATURES

Cold Start (Startup in Battery Mode During a Power Failure)

Cold-start operation supported

High Availability UPS Features

Hot swappable batteries

Green Energy-Saving Features

95% Efficiency

CERTIFICATIONS

UPS Certifications

Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category B (EMI)

 

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Tower
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 1500VA
Output Voltage 120V AC