Call toll free: 1-866-311-1945 | sales@excessups.ca
Your Region:

Tripp Lite SmartPro 2200VA 1900W RM 4U 120V SMART2200CRMXL - Refurbished

Tripp Lite SmartPro 2200VA 1900W RM 4U
Model: SMART2200CRMXL
Input: NEMA 5-20P (120V - 20A)
Output: (4) NEMA 5-15R, (4) NEMA 5-15/20R
Line-Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included

Usually ships in 15-20 days

Usually ships in 15-20 days

Usually ships in 15-20 days

CAD $824.99
Availability: On backorder

Usually ships in 15-20 days

Description

Details

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartPro UPS 2200VA 1900W, RM, 4U, 120V
Condition:
New batteries, refurbished UPS
Part Number:
SMART2200CRMXL

Maximum output: 1900W / 2200VA
Typical backup time
at half load:14.3 minutes (950 Watts)
Typical backup time
at full load: 4 minutes (1900 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartPro 2200VA 1900W RM 120V SMART2200CRMXL Manual


SMART2200CRMXL - Tripp Lite SmartPro 2200VA Specifications:

Input:

Rated input current (Maximum Load)

16A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

NEMA 5-20P

Input Circuit Breakers

20A

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Recommended Electrical Service

20A 120V

Input Phase

Single-Phase

Output:

Output Volt Amp Capacity (VA)

2200

Output Capacity (kVA)

2.20

Output Watt Capacity (Watts)

1900

Output kW Capacity (kW)

1.90

Power Factor

0.86

Nominal Voltage Details

120v nominal output in battery mode

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode)

-18%, +8%

Output Voltage Regulation (Battery Mode)

+/- 5%

Load Management Receptacles

Three switchable single-outlet 5-15R load banks

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Nominal Output Voltage(s) Supported

110V; 115V; 120V

Output Receptacles

(4) NEMA 5-15R

(4) NEMA 5-15/20R

Individually Controllable Load Banks

Yes


Battery:

Battery Type

Valve Regulated Lead Acid (VRLA)

Full Load Runtime (min.)

11 min. (1900w)

Half Load Runtime (min.)

28 min. (950w)

Expandable Battery Runtime

Extended runtime supported via optional external battery packs

External Battery Pack Compatibility

BP48V24-2U  (limit 1);  BP48V48RT4U  (multi-pack compatible);  BP48V27- 2US  (multi-pack compatible)

DC System Voltage (VDC)

48

Battery Recharge Rate (Included Batteries) 

Less than 3.6 hours from 10% to 90% (typical, full load discharge)

Battery Access

Front panel battery access door

Internal UPS Replacement Battery Cartridge

RBC94-2U  (quantity 2)

Battery Replacement Description

Hot-swappable, user replaceable batteries

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145

Overvoltage Correction

Input voltages between 127 and 145 are reduced by 12%

Undervoltage Correction

Input voltages between 92 and 107 are boosted by 14%

Severe Undervoltage Correction 

Input voltages between 83 and 95 are boosted by 24%


User Interface, Alerts & Controls:

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; rear panel protected switches support low/high charger settings

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate lowbattery status

Audible Alarm

Audible alarm indicates power-failure, overload and low-battery conditions

LED Indicators

5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

570

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Primary Form Factor

Rackmount

Cooling Method

Fan

Included Mounting Accessory Description 

Included 2POSTRMKITWM mounting accessory enables 2-post rackmount installation

Installation Form Factors Supported with Included Accessories

2 post 19 inch rackmount

Installation Form Factors Supported with Optional Accessories

4 post rackmount full-depth ( 4POSTRAILKIT ); 4 post rackmount short-depth ( 4POSTRAILKITWM ); Tower ( 2- 9USTAND )

Minimum Required Rack Depth with External Battery Pack (cm)

64

Minimum Required Rack Depth with External Battery Pack (in.)

58

Minimum Required Rack Depth without External Battery Pack (in.)

22.8

Optional Mounting Accessory Notes

Optional  2-9USTAND  enables upright tower UPS placement;  4POSTRAILKIT  mounting bracket enables installation in 4 post racks from 20.5 to 36 inches;  4POSTRAILKITWM  enables installation in 4-post short-depth racks from 14.5 to 23.5 inches (368 to 597mm)

Primary UPS Depth (mm)

452

Primary UPS Height (mm)

175

Primary UPS Width (mm)

439

Rack Height

4U

Shipping Dimensions (hwd / cm)

35.56 x 58.42 x 59.69

Shipping Dimensions (hwd / in.)

14.00 x 23.00 x 23.50

Shipping Weight (kg)

56.25

Shipping Weight (lbs.)

124.00

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

17.50 x 43.94 x 45.21

UPS Power Module Dimensions (hwd, in.)

6.89 x 17.30 x 17.80

UPS Power Module Weight (kg)

45.50

UPS Power Module Weight (lbs.)

100.3

 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

242

Battery Mode BTU / Hr. (Full Load)

885

AC Mode Efficiency Rating (100% Load)

97%

Audible Noise

45 dBA maximum, front side 1m


Communications:

Network Management Cards

SNMPWEBCARD ;  WEBCARDLX ;  RELAYIOCARD

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Network Management Card Description

Network management card optional

Communications Interface

DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 2200VA
Output Voltage 120V AC
PDU Total Outlets No

You may also be interested in

Related Products