Call toll free: 1-866-311-1945 | sales@excessups.ca
Your Region:

Tripp Lite SmartOnline 10000VA 9000W RM 6U 208V/240V SU10000RT3U - Refurbished

Tripp Lite SmartOnline 10kVA 9kW RM 6U 208V/240V
Model: SU10000RT3U
Input: Hardwire (208V-240V - 60A)
Output: (4) L6-20R, (2) L6-30R
Double Conversion Online UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included
CAD $3,849.99
Availability: In stock

Description

Details

Love Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 10,000VA 9,000W, RM, 6U, 60A, 208V/240V, New Batteries, Refurbished UPS
Condition:
New batteries, refurbished UPS
Part Number:
SU10000RT3U

Maximum output: 9,000W / 10,00VA
Typical backup time
at half load: 12.5 minutes (4500 Watts)
Typical backup time
at full load: 4.3 minutes (9000 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 10000VA 9000W RM 6U 208V/240V SU10000RT3U User's Manual


SU10000RT3U - Tripp Lite SmartOnline 10000VA Specifications:

Output:

Output Volt Amp Capacity (VA)

10000

Output kVA Capacity (kVA)

10

Output Watt Capacity (Watts)

9000

Output kW Capacity (kW)

9.0

Power Factor

0.9

Crest Factor

3:1

Nominal Voltage Details

Voltage selection via front panel LCD interface

Frequency Compatibility

50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion

Frequency Compatibility Details

Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (No de-rating); Output frequency regulation +/- 0.05Hz (free running)

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Output Circuit Breakers

20A double-pole (x2) protects 2 L6-20R outlets each,
30A double-pole (x2) protects 1 L6-30R outlet each

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Output Capacity Details

Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less

Nominal Output Voltage(s) Supported

200V; 208V; 240V

Output Receptacles

(4) NEMA L6-20R

(2) NEMA L6-30R

Individually Controllable Load Banks

No


Input:

Rated input current (Maximum Load)

56.1A (200V), 54A (208V), 51A (220V), 48.8A (230V), 46.8A (240V)

Nominal Input Voltage(s) Supported

200V AC; 208V AC; 240V AC

UPS Input Connection Type

Hardwire

 

UPS Input Connection Description

3 wire single phase input (L1, L2, G)

Recommended Electrical Service

60A

Input Phase

Single-Phase


Battery:

Full Load Runtime (min.)

4.3 min. (9000w)

Half Load Runtime (min.)

12.5 min. (4500w)

Expandable Battery Runtime

Supports extended runtime with optional external battery packs

External Battery Pack Compatibility

BP240V10RT3U ; BP240V787C-1PH

DC System Voltage (VDC)

240

Battery Recharge Rate (Included Batteries) 

Less than 6 hours from 10% to 90% (typical, full load discharge)

Battery Replacement Description

Hot-swappable, user replaceable external battery packs

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

2% output voltage regulation in standard online, double-conversion mode

Overvoltage Correction

Corrects overvoltages up to 300V

Undervoltage Correction

Corrects undervoltages as low as 100V


User Interface, Alerts & Controls:

Front Panel LCD Display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement

Alarm Cancel Operation

Alarm cancel switch

Audible Alarm

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

2565

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Battery Pack Dimensions (hwd / in.)

5.25 x 17.5 x 25

Included Battery Pack Weight (kg)

71.99

Included Battery Pack Weight (lbs.)

158.7

Included Mounting Accessory Description

Not included

Installation Form Factors Supported:

4 post 19 inch rackmount

Installation Form Factors Supported with Optional Accessories

2 post rackmount ( 2POSTRMKITHD )

Maximum Device Depth (cm)

82.55

Maximum Device Depth (in.)

32.5

Maximum Device Depth (mm)

826

Minimum Required Rack Depth (cm)

95.25 

Minimum Required Rack Depth (inches)

37.5

Optional Mounting Accessory Notes

2 sets of  2POSTRMKITHD  required for 2 post rackmount installation of separate power module and battery pack

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

656

Primary UPS Height (mm)

131

Primary UPS Width (mm)

445

Rack Height

6U

Shipping Dimensions (hwd / cm)

78.74 x 66.04 x 104.14

Shipping Dimensions (hwd / in.)

31.00 x 26.00 x 41.00 

Shipping Weight (kg)

136.08

Shipping Weight (lbs.)

300.00

Unit Dimension Details

Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710 PDU with bypass; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

13.06 x 44.45 x 65.58

UPS Power Module Dimensions (hwd, in.)

5.14 x 17.5 x 25.82

UPS Power Module Weight (kg)

19.50

UPS Power Module Weight (lbs.)

43 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

3415

AC Economy Mode BTU / Hr. (Full Load)

1280

Battery Mode BTU / Hr. (Full Load)

4593

AC Mode Efficiency Rating (100% Load)

91%

AC Economy Mode Efficiency Rating (100% Load)

96%

Operating Elevation (ft.)

0-3000m (0 to 10,000 ft.)

Audible Noise

60 dBA at front side 1 meter

Operating Elevation (m)

0-3000 m


Communications:

Network Management Cards

SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD

Network Monitoring Port Description

Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB, DB9 serial and EPO cables included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Communications Interface

USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 208V AC, 240V AC
Output (VA) 10000VA
Output Voltage 208V AC, 240V AC
PDU Total Outlets No