Tripp Lite SmartOnline 3000VA 2700W RM 2U 120V SU3000RTXL2U - Refurbished

Tripp Lite SmartOnline 3000VA 2700W RM 2U 120V
Model: SU3000RTXL2U
Input: NEMA L5-30P (120V - 30A)
Output: (6) 5-15/20R, (1) L5-30R
Double Conversion Online UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
CAD $769.99
Availability: In stock

Description

Details

Love Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 3000VA 2700W, RM, 2U, 30A, 120V, New Batteries, Refurbished UPS
Condition:
New batteries, refurbished UPS
Part Number:
SU3000RTXL2U

Maximum output: 2700W / 3000VA
Typical backup time
at half load: 13.8 minutes (1350 Watts)
Typical backup time
at full load: 4.8 minutes (2700 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 3000VA 2700W Tower 120V SU3000RTXL2U Manual


SU3000RTXL2U - Tripp Lite SmartOnline 3000VA Specifications:

Input:

Rated input current (Maximum Load)

24A maximum

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

NEMA L5-30P

Recommended Electrical Service

30A 120V

Input Phase

Single-Phase

Input Cord Length (ft.)

10

Input Cord Length (m)

3.05

Output:

Output Volt Amp Capacity (VA)

3000

Output kVA Capacity (kVA)

3

Output Watt Capacity (Watts)

2700

Output kW Capacity (kW)

2.70

Power Factor

0.9

Crest Factor

3:1

Nominal Voltage Details

120V default

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Accepts 40 to 70Hz input frequency. Output frequency matches input nominal on startup, defaults to 60 Hz on coldstart. Frequency conversion from 60 to 50 Hz -or- 50 to 60 Hz supported. Output capacity de-rates to 70% of
normal levels during frequency conversion operation.

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Load Management Receptacles

Two switchable three-outlet load banks

Output Circuit Breakers

20A (x2) - each breaker protects 3 5-15/20R outlets, L5-30R outlet is un-breakered

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Output Capacity Details

INVERTER SHORT-CIRCUIT PROTECTION: Inverter short-circuit protection is electrically protected; OVERLOAD
CAPACITY: Supports inverter operation up to 105% load continuously, 125% for 30 seconds, 150% for 10 seconds
and >150% for 0.5 seconds before switching to BYPASS (when bypass input voltage and frequency are WITHIN
bypass limits of 120V ±10%) or SHUTDOWN (when bypass input voltage or frequency are OUTSIDE bypass limits
of 120V ±10%).

Nominal Output Voltage(s) Supported

100V; 110V; 115V; 120V; 127V

Output Receptacles

(6) NEMA 5-20R

(1) NEMA L5-30R

Individually Controllable Load Banks

 Yes


Battery:

Full Load Runtime (min.)

4.8 min. (2700w)

Half Load Runtime (min.)

13.8 min. (1350w)

Expandable Battery Runtime

Supports extended runtime with optional external battery packs

External Battery Pack Compatibility

 BP72V15-2U  (limit 1);  BP72V28RT-3U  (multi-pack compatible);  BP72V18-2US  (multi-pack compatible)

DC System Voltage (VDC)

72

Battery Recharge Rate (Included Batteries) 

Less than 8.1 hours from 10% to 90% (typical, full load discharge)

Internal UPS Replacement Battery
Cartridge

See RBC selector guide (replacement battery part number is also labeled on the internal battery door)

Battery Access

Front panel battery access door

Battery Replacement Description

Hot-swappable, user replaceable batteries

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

ONLINE MODE: 2% output voltage regulation during overvoltages to 150

Undervoltage Correction

2% output voltage regulation during undervoltages to 80V (66-100% load)

Severe Undervoltage Correction

2% output voltage regulation during undervoltages to 70V (33-66% load) or 60V (under 33% load)


User Interface, Alerts & Controls:

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch

Audible Alarm

Audible alarm indicates power failure, low battery, overload, replace battery and EPO operation

LED Indicators

14 LEDs indicate line power, online mode, economy/bypass mode, on-battery, overload, battery low, replace battery and fault status information; 4-LED meter displays load and battery charge levels; LED panel rotates for viewing in rack/tower formats


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

504

EMI / RFI AC Noise Suppression

Yes

AC Suppression Response Time

Instantaneous


Physical:

Cooling Method

Fan

Included Mounting Accessory
Description

Includes 4 post rackmount installation accessories

Installation Form Factors Supported
with Optional Accessories

2 post rackmount ( 2POSTRMKITWM ); Tower ( 2-9USTAND )

Minimum Required Rack Depth with
External Battery Pack (cm)

77

Minimum Required Rack Depth with
External Battery Pack (in.)

30.25

Minimum Required Rack Depth
without External Battery Pack (cm)

74

Minimum Required Rack Depth
without External Battery Pack (in.)

29.25

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

616

Primary UPS Height (mm)

88

Primary UPS Width (mm)

438

Rack Height

2U

Shipping Dimensions (hwd / cm)

24.00 x 59.99 x 76.00

Shipping Dimensions (hwd / in.)

9.45 x 23.62 x 29.92 

Shipping Weight (kg)

39.46

Shipping Weight (lbs.)

87.00

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

8.79 x 43.79 x 61.60

UPS Power Module Dimensions (hwd, in.)

3.46 x 17.24 x 24.25

UPS Power Module Weight (kg)

31.17

UPS Power Module Weight (lbs.)

68.72 

 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.

Relative Humidity

5 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

531

AC Economy Mode BTU / Hr. (Full Load)

484.5

Battery Mode BTU / Hr. (Full Load)

1037

AC Economy Mode Efficiency Rating (100% Load)

95%

Audible Noise

50 dBA max, front-side @ 1m


Communications:

Network Management Cards

 WEBCARDLX

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; DB9 port supports RS232 and contact closure communications

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports and modify the UPS Power Strategy settings download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB and DB9 cabling included

WatchDog Compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

Communications Interface

Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 3000VA
Output Voltage 120V AC
PDU Total Outlets No