1-866-311-1945 sales@excessups.ca

Canada Canada [change]

Tripp Lite SmartOnline UPS 5000VA 208-240V SU5000RT3UHV - Refurbished

Refurbished Tripp Lite SmartOnline UPS 5000VA SU5000RT3UHV
Model:
SU5000RT3UHV
Input: NEMA L6-30P (208V 30A)
Output:
(2) NEMA L6-20R, (2) NEMA L6-30R
Double-Conversion UPS, Pure Sine wave Output
New batteries, refurbished UPS
1 Year Warranty Included

Availability: In stock

CAD $1,499.99
Shipping Info
  • This item is in stock and ships within 1 business day
  • We will gladly accept returns for any reason within 30 days of receipt of delivery
  • Continental USA & Canada

Description

Details

Manufacturer: Tripp Lite
Model: Refurbished SmartOnline UPS 5000VA 208-240V with New Batteries
Condition: New batteries, refurbished UPS
Part Number: SU5000RT3UHV
Maximum output:
3800W / 5000VA
Typical backup time
at half load: 14.0minutes (1900 Watts)
Typical backup time
at full load: 6.0 minutes (3800 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline UPS 5000VA SU5000RT3UHV Manual

 


 

SU5000RT3UHV - Tripp Lite SmartOnline UPS 5000VA Specifications:

OUTPUT
Output Volt Amp Capacity (VA) 5000
Output kVA capacity (kVA) 5
Output Watt Capacity (watts) 3800
Output kW capacity 3.8
Output power factor 0.8
Crest Factor 3:1
Nominal Output Voltage(s) Supported 120V; 208V; 240V
Nominal Voltage details 240/120V or 208/120V split phase output
Frequency compatibility 60 Hz
Output voltage regulation (line mode) +/- 3%
Output voltage regulation (Economy line mode) +/- 10%
Output voltage regulation (Battery mode) +/- 3%
Built-in UPS output receptacles 8 5-15/20R outlet(s); 2 L6-20R outlet(s); 2 L6-30R outlet(s)
Output circuit breaker 20A branch rated breakers (x4) protect 2 5-15/20R outlets each, 20A double pole breakers (x2) protect one L6-20R each, L6-30R outlets are unbreakered
Output AC waveform (AC mode) Sine wave
Output AC waveform (battery mode) Pure Sine wave
INPUT
Rated input current (at maximum load) 21A
Nominal Input Voltage(s) Supported 208V AC / 120V AC (4 wire split single phase); 240V AC /120V AC (4 wire split single phase)
UPS input connection type L14-30P
UPS input connection description 4 wire split-phase input (L1, L2, N, G)
UPS Input cord length (ft.) 10
UPS Input cord length (m) 3
Recommended Electrical Service 30A 208/120V Split Phase
Input cord length (m) 3
Phase Single-Phase
BATTERY
Full load runtime (minutes) 6 min. (3800w)
Half load runtime (minutes) 14 min. (1900w)
Expandable battery runtime Supports extended runtime with optional external battery packs
External battery pack compatibility BP192V12-3U; BP192V557C-1PH; BP192V787C-1PH; BP192V1037C-1PH; BP192V1407C-1PH
DC system voltage (VDC) 192
Battery recharge rate (included batteries) Less than 6 hours from 10% to 80%
Replacement battery cartridge (internal UPS battery replacement) RBC9-192
Battery Access Front panel battery access door
Battery replacement description Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage regulation description Online, double-conversion power conditioning
Overvoltage correction 3% output voltage regulation during overvoltages to 140 (measured L1-N : L2-N)
Undervoltage correction 2% output voltage regulation during undervoltages to 65 (measured L1-N : L2-N)
LEDS ALARMS & SWITCHES
LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
Alarms Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel operation Alarm cancel switch
Switches Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads. Battery Charge level switch allows the charger output to be adjusted to a higher charge rate when additional battery packs are added.
SURGE / NOISE SUPPRESSION
UPS AC suppression response time Instantaneous
EMI / RFI AC noise suppression Yes
PHYSICAL
Installation form factors supported with optional accessories 2 post rackmount (2POSTRMKITHD); Tower (2-9USTAND)
Primary form factor Rackmount
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) 7 x 17.5 x 30.8
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) 17.8 x 44.4 x 78.1
Installed whole system maximum rack depth (inches) 30.8
Installed whole system maximum rack depth (cm) 78.1
Rack Height 4U
Secondary form factor Tower (requires 2-9USTAND)
UPS / Power Module weight (lbs) 149.6
UPS / Power Module weight (kg) 67.9
UPS dimensions details 4U UPS with internal batteries
UPS Shipping dimensions (height x width x depth / inches) 13.2 x 37 x 23
UPS Shipping dimensions (height x width x depth / cm) 33.7 x 94 x 58.4
Shipping weight (lbs) 189.2
Shipping weight (kg) 85.9
Cooling method Fan
UPS housing material Steel
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC mode BTU / hr. (full load) 1435.6
Battery mode BTU / hr. (full load) 1277.8
Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.)
Audible Noise 60 dBA at front side 1 meter
Operating Elevation (m) 0-3000 m
COMMUNICATIONS
Communications interface USB (HID enabled); DB9 Serial; Contact closure; EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring port description RS232 and contact closure communications are supported on one DB9 port
PowerAlert software Included
Communications cable USB and DB9 cabling included
LINE / BATTERY TRANSFER
Transfer time No transfer time (0 ms.) in online, double-conversion mode
Low voltage transfer to battery power (setpoint) 65V (L1-N:L2-N)
High voltage transfer to battery power (setpoint) 140V (L1-N:L2-N)
SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure) Cold-start operation supported
High availability UPS features Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module; Hot swappable batteries
Green & high efficiency features High efficiency economy mode operation; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category A (EMI)

 

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage No
Output (VA) 5000VA
Output Voltage No

You Might Also Like