Call toll free: 1-866-311-1945 | sales@excessups.ca
Your Region:

Tripp Lite SmartOnline 6000VA 5400W RM 4U 200/240V SU6000RT4UHV - Refurbished

Tripp Lite SmartOnline 6000VA 5400W RM 4U
Model: SU6000RT4UHV
Input: NEMA L6-30P (208V - 30A)
Output: (2) NEMA L6-20R, (2) NEMA L6-30R
Double Conversion Online UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
  • 1 Year Included
    Included
  • 2 Year
    +CAD $440.00
  • 3 Year
    +CAD $770.00

* Required Fields

CAD $2,199.99
Availability: In stock

Description

Details

Love Manufacturer: Tripp Lite
Model:
Tripp Lite SmartOnline UPS 6000VA 5400W, Tower, 30A, 200/240V, New Batteries, Refurbished UPS
Condition:
New batteries, refurbished UPS
Part Number:
SU6000RT4UHV

Maximum output: 5400W / 6000VA
Typical backup time
at half load: 8.5 minutes (2700 Watts)
Typical backup time
at full load: 2 minutes (5400 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline 6000VA 5400W Tower 200/240V SU6000RT4UHV Manual


SU6000RT4UHV - Tripp Lite SmartOnline 6000VA Specifications:

Input:

Rated input current (Maximum Load)

31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)

Nominal Input Voltage(s) Supported

200V AC; 208V AC; 240V AC

Nominal Input Voltage Description

Factory configured to 208V

UPS Input Connection Type

NEMA L6-30P

UPS Input Cord Length (ft.)

10

UPS Input Cord Length (m)

3.1

Recommended Electrical Service

30A

Input Phase

Single-Phase

Output:

Output Volt Amp Capacity (VA)

6000

Output kVA Capacity (kVA)

6

Output Watt Capacity (Watts)

5400

Output kW Capacity (kW)

5.4

Power Factor

0.9

Crest Factor

3:1

Nominal Voltage Details

Voltage selection via front panel LCD interface

Frequency Compatibility

50 / 60 Hz

Frequency Compatibility Details

Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)

Output Voltage Regulation (Line Mode)

+/- 2%

Output Voltage Regulation (Economy Line Mode)

+/- 10%

Output Voltage Regulation (Battery Mode)

+/- 2%

Output Receptacle Details

Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement

Output Circuit Breakers

20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered

Output AC Waveform (AC Mode)

Pure Sine wave

Output AC Waveform (Battery Mode)

Pure Sine wave

Output Capacity Details

Output capacity de-rates to 4992 watts when used at 208V nominal; Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as the overload is cleared.

Nominal Output Voltage(s) Supported

200V; 208V; 240V

Output Receptacles

(2) NEMA L6-20R

(2) NEMA  L6-30R

Individually Controllable Load Banks

No


Battery:

Full Load Runtime (min.)

2 min. (5400W)

Half Load Runtime (min.)

8.5 min. (2700W)

Expandable Battery Runtime

Runtime is expandable with external battery packs

External Battery Pack Compatibility

 BP192V12-3U ;  BP192V5RT2U  (limit 1);  BP192V787C-1PH

DC System Voltage (VDC)

192

Battery Recharge Rate (Included Batteries) 

6 hours from 10% to 90% (typical, full load discharge)

Internal UPS Replacement Battery Cartridge

RBC5-192

Battery Access

Front panel battery access door

Battery Replacement Description

Hot-swappable, user replaceable internal batteries

Expandable Runtime

Yes


Voltage Regulation:

Voltage Regulation Description

Online, double-conversion power conditioning

Overvoltage Correction

Corrects overvoltages as high as 300V (<90% load) and 280V (full load)

Undervoltage Correction

Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly


User Interface, Alerts & Controls:

Front Panel LCD Display

Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)

Switches

Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads.

Alarm Cancel Operation

Alarm cancel switch

Audible Alarm

Unique audible alarms for all major UPS, environmental and power conditions (see manual)

LED Indicators

6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

2595

UPS AC Suppression Response Time

Instantaneous 

EMI / RFI AC Noise Suppression

Yes


Physical:

Cooling Method

Fan

Included Mounting Accessory Description

Includes 4 post rackmount installation accessories

Installation Form Factors Supported
with Optional Accessories

2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )

Maximum Device Depth (cm)

52.58

Maximum Device Depth (in.) 

20.7

Maximum Device Depth (mm)

526

Minimum Required Rack Depth with
External Battery Pack (cm)

73

Minimum Required Rack Depth with
External Battery Pack (in.)

28.67

Minimum Required Rack Depth
without External Battery Pack (cm)

65

Minimum Required Rack Depth
without External Battery Pack (in.)

25.67

Primary Form Factor

Rackmount

Primary UPS Depth (mm)

525

Primary UPS Height (mm)

174

Primary UPS Width (mm)

445

Rack Height

4U

Shipping Dimensions (hwd / cm)

76.20 x 91.44 x 60.96

Shipping Dimensions (hwd / in.)

30.00 x 36.00 x 24.00 

Shipping Weight (kg)

86.18

Shipping Weight (lbs.)

190.00

UPS Housing Material

Steel

UPS Power Module Dimensions (hwd, cm)

17.40 x 44.45 x 52.50

UPS Power Module Dimensions (hwd, in.)

6.85 x 17.5 x 20.67

UPS Power Module Weight (kg)

48.99

UPS Power Module Weight (lbs.)

108 

 


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

1767

AC Economy Mode BTU / Hr. (Full Load)

768

Battery Mode BTU / Hr. (Full Load)

2279

AC Mode Efficiency Rating (100% Load)

90%

AC Economy Mode Efficiency Rating (100% Load) 

96%

Operating Elevation (ft.)

Up to 6500 ft

Audible Noise

60 dBA at front side 1 meter

Operating Elevation (m)

0-2000m


Communications:

Network Management Cards

SNMPWEBCARD ;  TLNETCARD ;  WEBCARDLX ;  MODBUSCARD ;  RELAYIOCARD

Network Monitoring Port Description

Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert

Communications Cable

USB, DB9 serial and EPO cables included

WatchDog Compatibility

Yes

Communications Interface

DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage 208V AC, 240V AC
Output (VA) 6000VA
Output Voltage 240V AC
PDU Total Outlets No

You may also be interested in

Related Products