1-866-311-1945 sales@excessups.ca

Canada Canada [change]

Tripp Lite SmartOnline UPS 6000VA 200-240V SU6000RT4UHV - Refurbished

Refurbished Tripp Lite SmartOnline UPS 6000VA SU6000RT4UHV
Model:
SU6000RT4UHV
Input: NEMA L6-30P (208V 30A)
Output:
(2) NEMA L6-20R, (2) NEMA L6-30R
Double-Conversion UPS, Pure Sine wave Output
New batteries, refurbished UPS
1 Year Warranty Included

Availability: In stock

CAD $1,799.99

* Required Fields

Shipping Info
  • This item is in stock and ships within 1 business day
  • We will gladly accept returns for any reason within 30 days of receipt of delivery
  • Continental USA & Canada

Description

Details

Manufacturer: Tripp Lite
Model: Refurbished SmartOnline UPS 6000VA 200-240V with New Batteries
Condition: New batteries, refurbished UPS
Part Number: SU6000RT4UHV
Maximum output:
5400W / 6000VA
Typical backup time
at half load: 8.5 minutes (2700 Watts)
Typical backup time
at full load: 2.0 minutes (5400 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartOnline UPS 6000VA SU6000RT4UHV Manual

 


 

SU6000RT4UHV - Tripp Lite SmartOnline UPS 6000VA Specifications

Output:

GENERAL INFO
Intended Market Class (AS400)120=N. America, 230= ROW 120
OUTPUT
Output Volt Amp Capacity (VA) 6000
Output kVA capacity (kVA) 6.0
Output Watt Capacity (watts) 5400
Output kW capacity 5.4
Output power factor 0.9
Output Capacity Details Output capacity de-rates to 4992 watts when used at 208V nominal
Crest Factor 3:1
Nominal Output Voltage(s) Supported 200V; 208V; 240V
Frequency compatibility 50 / 60 Hz
Frequency compatibility details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Output voltage regulation (line mode) +/- 2%
Output voltage regulation (Economy line mode) +/- 10%
Output voltage regulation (Battery mode) +/- 2%
Built-in UPS output receptacles 2 L6-20R outlet(s); 2 L6-30R outlet(s)
Output receptacle details Output receptacles and input line cord are mounted on a detachable PDU backplate with bypass switch to enable hot-swappable power module replacement
Output circuit breaker 20A breaker protects L6-20R outlets, L6-30R outlets are unbreakered
Output AC waveform (AC mode) Pure Sine wave
Output AC waveform (battery mode) Pure Sine wave
INPUT
Rated input current (at maximum load) 31.9A (200V), 30.6A (208V), 29A (220V), 27.7A (230V), 26.6A (240V)
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 240V AC
Nominal input voltage description Factory configured to 208V
UPS input connection type L6-30P
UPS Input cord length (ft.) 10
UPS Input cord length (m) 3
Recommended Electrical Service 30A
Phase Single-Phase
BATTERY
Full load runtime (minutes) 2 minutes (5400 watts)
Half load runtime (minutes) 8.5 minutes (2700 watts)
Expandable battery runtime Runtime is expandable with external battery packs
External battery pack compatibility BP192V12-3U; BP192V557C-1PH; BP192V787C-1PH; BP192V1037C-1PH; BP192V1407C-1PH
DC system voltage (VDC) 192
Battery recharge rate (included batteries) 6 hours from 10% to 90% (internal batteries)
Replacement battery cartridge (internal UPS battery replacement) RBC5-192
Battery Access Front panel battery access door
Battery replacement description Hot-swappable, user replaceable internal batteries
VOLTAGE REGULATION
Voltage regulation description Online, double-conversion power conditioning
Overvoltage correction Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
Undervoltage correction Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly
LEDS ALARMS & SWITCHES
LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
Alarms Unique audible alarms for all major UPS, environmental and power conditions (see manual)
Alarm cancel operation Alarm cancel switch
Switches Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads.
SURGE / NOISE SUPPRESSION
UPS AC suppression response time Instantaneous
EMI / RFI AC noise suppression Yes
PHYSICAL
Installation form factors supported with optional accessories 2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)
Primary form factor Rackmount
UPS / Power Module dimensions in primary form factor (height x width x depth / inches) 6.85 x 17.5 x 20.7
UPS / Power Module dimensions in primary form factor (height x width x depth / cm) 17.4 x 44.5 x 52.6
Rack Height 4U
Secondary form factor Tower
UPS / Power Module weight (lbs) 108
UPS / Power Module weight (kg) 49
UPS Shipping dimensions (height x width x depth / inches) 12.7 x 23.6 x 29.1
UPS Shipping dimensions (height x width x depth / cm) 32.3 x 59.9 x 73.9
Shipping weight (lbs) 158
Shipping weight (kg) 71.7
Cooling method Fans
UPS housing material Steel
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC mode BTU / hr. (full load) 1767
AC economy mode BTU / hr. (full load) 707
Battery mode BTU / hr. (full load) 1784
AC economy mode efficiency rating (100% load) 96%
Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.)
Audible Noise 60 dBA at front side 1 meter
Operating Elevation (m) 0-3000 m
COMMUNICATIONS
Communications interface USB (HID enabled); DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
Network monitoring port description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
PowerAlert software Included
Communications cable USB, DB9 serial and EPO cables included
WatchDog compatibility Yes
LINE / BATTERY TRANSFER
Transfer time No transfer time (0 ms.) in online, double-conversion mode
Transfer time (economy mode) 8 ms. typical power failure response in optional economy mode
Low voltage transfer to battery power (setpoint) 156V (full load) / 100V (50% load or less, derates linearly)
High voltage transfer to battery power (setpoint) 280V (full load) / 300V (90% load or less)
SPECIAL FEATURES
Cold Start (startup in battery mode during a power failure) Cold-start operation supported
High availability UPS features Automatic inverter bypass; Manual bypass switch; Detachable hot-swap PDU; Hot swappable UPS power module; Hot swappable batteries
Green & high efficiency features High efficiency economy mode operation; Support for daily startup and shutoff; Schedulable daily hours of economy mode operation
CERTIFICATIONS
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
UPS Certification details IEC 61000-4-5 1995 B Surge Immunity

 

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Rackmount
Waveform in Battery Mode Pure Sinewave
Input Voltage No
Output (VA) 6000VA
Output Voltage No

You Might Also Like