APC AP7841 Rack PDU Metered 4992VA 30A 200-240V, Zero U, IN: IEC 60309 2P+E - Refurbished

APC AP7841 Rack PDU, Metered, Zero U, 30A, 200/240V
Model: AP7841
Input: 200V-230V

Input Connection: IEC 60309 2P+E
Output: 200V-240V 
Output Connections: (20) C13, (4) C19
Refurbished PDU
1 Year Replacement Warranty

In stock

Manufacturer: APC
Model Description: APC Metered Rack PDU, Zero U, 30A 200V-230V, (20) C13 & (4) C19
Condition: Refurbished
Part Number: AP7841
Output Voltage: 200V, 208V, 230V, 240V
Input Voltage: 200V, 208V, 230V 30A
Warranty: 1 Year Full Replacement Warranty

Description: APC AP7841 Metered Rack PDU, ZeroU, 30A, 200–240V, (20) C13 & (4) C19. Model: AP7841. Input Connection: IEC 60309 2P+E . Output Connections: (20) IEC C13, (4) IEC C19. Provides up to 4992VA capacity with input-level metering for real-time load monitoring in amps. Supports remote management via built-in Ethernet (SNMP, Web, Telnet, SSH) with configurable alarms, event logging, and email/SNMP notifications. Vertical 0U design for high-density rack integration without consuming rack space. Refurbished unit. 1 Year Full Replacement Warranty Included.

 

 

APC AP7841 Rack PDU Metered, 0u, 4992VA, 30A, 200-240V - Product data sheet

 



AP7841- APC Metered Rack PDU Specifications:

Key Features:

Output Connections

(4) IEC 60320 C19

(20) IEC 60320 C13

Nominal Output Voltage

200V, 208V, 230V, 240V

Nominal Input Voltage

200V, 208V, 230V

Input Connections

IEC 60309 2P+E


Output:

Overload Protection

Yes

Maximum Total Current Draw

30


Input:

Input frequency

50/60 Hz

Acceptable Input Voltage

200 - 240VAC

Number of Power Cords

1

Load Capacity

4992VA

Maximum Input Current

30A

Regulatory Derated Input Current (North America)

24A


Physical:

Maximum Height

63.74 inches (1619mm, 161.9cm)

Maximum Width

2.2 inches (56mm, 5.6cm)

Maximum Depth

1.73 inches (44mm, 4.4cm)

Net Weight

12.52 lbs. (5.68kg)

Color

Black

 

Communications & Management :

Network Interface Built-in Ethernet port (10/100Base-T)
Remote Management Web (HTTP/HTTPS), SNMP (v1/v2c/v3), Telnet, SSH
User Interface Integrated web interface + local LED display for current (amps)
Monitoring Real-time current monitoring (total load in amps)
Metering Type Input-level metering (aggregate load monitoring)
Alarms User-configurable thresholds for load (overload warnings)
Notifications SNMP traps, email alerts, syslog support
Logging Event logging and power data logs via network interface
Security HTTPS, SNMPv3, SSH, user authentication and role-based access
Network Management Compatible with APC PowerNet MIB and management platforms
Firmware Upgrade

Supported via network (web/FTP/SCP)

Serial Access

RJ-45 serial port for local configuration

IP Configuration

DHCP, BOOTP, or manual static IP setup

 

Environmental:

Operating Temperature

32 - 113 °F (0 - 45 °C)

Operating Relative Humidity

5 - 95%

Operating Elevation

0 - 10000ft (0 - 3048 meters)

Storage Temperature

-25 - 65°C

Storage Relative Humidity

5 - 95%

Storage Elevation

0 - 50000ft (0 - 15240 meters)