APC Back-UPS 650VA 360W 120V Output:(5)5-15R Batt, (2)5-15R Surge, BVN650M1-CA – Refurb

APC Back-UPS 650VA 360W 120V 15A Floor/Wall Mount 
Model: BVN650M1-CA
Input: NEMA 5-15P (120V - 15A)
Output: (5) NEMA 5-15R (Battery & Surge), (2) NEMA 5-15R (Surge)
Line Interactive UPS – Stepped Sinewave Output
New Batteries, Refurbished UPS

1 Year Warranty Included 

In stock

Manufacturer: APC
Model: APC Back-UPS 650VA 360W 120V
Condition: New batteries, Refurbished UPS
Part Number: BVN650M1-CA
Maximum output: 360W / 650VA
Typical backup time at half load: ~14 minutes (180 W)
Typical backup time at full load: ~3.5 minutes (360 W)
Warranty:  1 Year Full Replacement Warranty
 

APC Back-UPS 650VA 360W 120V - BVN650M1-CA - User's Manual

 


BVN650M1-CA Specifications:

Main:

Main Input Voltage

120 V

Rated Power in W

360 W

Rated Power in VA

650 VA

Output Connection Type

(5) NEMA 5-15R (Surge), (2) NEMA 5-15R (Battery & Surge)

Cable Length

6 ft (1.83 m)

Battery Type

Lead-acid internal, user replaceable

General:

Number of Power Module Free Slots

0

Number of Power Module Filled Slots

0

Redundant

No

 

 

Physical:

Height

5.5 in (139 mm)

Width

4.1 in (105 mm)

Depth

10.8 in (274 mm)

Net Weight

6.8 lb (3.1 kg)

Mounting Preference

No preference

Mounting Mode

Wall / Floor Mount

Two Post Mountable

0

USB Compatible

No

 

Input:

Input Frequency

50/60 Hz +/- 5 Hz auto-sensing

Input Voltage Limits

88 – 143 V

 

Output:

Max Configurable Power (Watts)

360 W

Max Configurable Power (VA)

650 VA

Output Frequency

50/60 Hz +/- 1 Hz unsynchronized

Topology

Line Interactive

Waveform Type

Stepped approximation to sinewave

Transfer Time

6 ms typical : 10 ms maximum

 

Conformance:

Product Certifications

cTUVus, CEC, ENERGY STAR V2.0 (USA)

 

Environmental:

Ambient Air Temperature for Operation

32 – 104 °F (0 – 40 °C)

Relative Humidity

0 – 90 %

Operating Altitude

0 – 6666 ft

Ambient Air Temperature for Storage

5 – 113 °F (-15 – 45 °C)

Storage Relative Humidity

0 – 95 % non-condensing

Storage Altitude

0 – 10000 ft (0 – 3048 m)

Acoustic Level

N/A

 

Batteries & Runtime:

Included Battery Modules

1

Battery Slots Empty

0

Typical Recharge Time

8 h

RBC Quantity

1

Battery Voltage

12 V

Battery Capacity

7.2 Ah

Battery Charger Power (Watts)

8 W

Replacement Battery

APCRBCV211

Battery Life

3 – 5 years

  

Communications & Management:

Alarm

Alarm when on battery: distinctive low battery alarm; overload continuous tone alarm

Control Panel

LED status display with online / on battery

  

Surge Protection and Filtering:

Surge Energy Rate

490 J

Filtering

Full time multi-pole noise filtering

Let Through Voltage Rating

N/A