Checkout using your account
Checkout as a new customer
Creating an account has many benefits:
APC Smart-UPS 3000VA 2700W LCD RM 2U with AP9631 NMC 120V
Model: SMT3000RM2UNC
Input: NEMA L5-30P (120V - 30A)
Output: (6) NEMA 5-15R, (2) NEMA 5-20R
Line-Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: APC
Model: APC Smart-UPS 3000VA 2700W LCD, RM, 2U, 30A, 120V - AP9631 Network card pre-installed
Condition: New batteries, refurbished UPS
Part Number: SMT3000RM2UNC
Maximum output: 2700W / 3000VA
Typical backup time at half load: 11.3 minutes (1350 Watts)
Typical backup time at full load: 3.2 minutes (2700 Watts)
Warranty: 1 year full replacement warranty
APC Smart-UPS 3000VA 2700W LCD RM 2U SMT3000RM2UNC AP9631 - User's Manual
SMT3000RM2UNC - APC Smart-UPS Specifications:
Main:
Main Input Voltage |
120V |
||||
Main Output Voltage |
120V |
||||
Rated power in W |
2700W |
||||
Rated power in VA |
2880VA |
||||
Input Connection Type |
|
||||
Output Connection Type |
|
||||
Number of Rack Unit |
2U |
||||
Cable Length |
8 ft (2.44 m) |
||||
Number of Cables |
1 |
||||
Battery Type |
Lead-acid Battery |
Physical:
Colour |
Black |
Height |
3.39 in (8.6 cm) |
Width |
18.90 in (48 cm) |
Depth |
26.89 in (68.3 cm) |
Net Weight |
97.62 lb(US) (44.28 kg) |
Mounting Location |
Front |
Two Post and Four Post Mountable |
Yes |
USB Compatible |
Yes |
Input:
Input Voltage Limits |
75 - 154V adjustable |
Network Frequency |
50/60 Hz +/- 3 Hz Auto-sensing |
Output:
Harmonic Distortion |
Less than 5% |
Maximum Configurable Power in VA |
2880 VA |
Maximum Configurable Power in W |
2700 W |
Transfer Time |
4 ms typical: 8 ms maximum |
UPS Type |
Line Interactive |
Wave Type |
Sine wave |
Output Frequency |
50/60 Hz +/- 3 Hz sync to mains |
Environmental:
Acoustic Level |
55 dBA |
Heat Dissipation |
348 Btu/h |
Operating Altitude |
0 - 10000 ft |
Ambient Air Temperature for Operation |
32 - 104°F (0 - 40°C) |
Ambient Air Temperature for Storage |
5 - 113 °F (-15 - 45°C) |
Storage Altitude |
0 - 50000 ft (0.00 - 15240.00 m) |
Relative Humidity |
0 - 95% |
Storage Relative Humidity |
0 - 95% |
Batteries & Runtime:
Extended Runtime |
0
|
Number of Battery Filled Slots |
0 |
Number of Battery Free Slots |
0 |
Battery Recharge Time |
3h |
Number of Battery Replacement Quantity |
1 |
Battery Life |
3 - 5 year(s) |
Replacement Battery |
RBC43 |
Communications & Management:
Alarm |
Alarm when on battery: distinctive low battery alarm: overload continuous tone alarm
|
Control Panel |
LED status display with on line: on battery: replace battery and overload indicators |
Free Slots |
0 |
Preinstalled Device |
AP9631 Network management card 2 with environmental monitoring |
Surge Protection and Filtering:
Surge Energy Rate |
459 J
|