Tripp Lite SM2200RMXL2UP 2200VA 1920W 120V 2U UPS AVR Output: (4)5-15R, (4)5-15/20R, Refurbished

Tripp Lite SmartPro 2200VA 1920W RM 2U
Model: SM2200RMXL2UP
Input: NEMA 5-20P (120V - 20A)
Output: (4) NEMA 5-15R, (4) NEMA 5-15/20R
Line Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included

In stock

Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro UPS 2200VA 1920W, RM, 20A, 120V, AVR
Condition: New Batteries, Refurbished UPS
Part Number: SM2200RMXL2UP
Maximum output: 1920W / 2200VA
Typical backup time at half load: 12 minutes (960 Watts)
Typical backup time at full load: 4.5 minutes (1920 Watts)
Output Waveform: Pure Sine Wave
Warranty: 1 Year Full Replacement Warranty

Description: Line-Interactive SmartPro UPS with pure sine wave output, automatic voltage regulation (AVR) and extended runtime capability. Designed for rackmount or tower installation (2U), it provides reliable protection for servers, networking equipment and telecom systems. Features hot-swappable batteries, LCD monitoring interface, USB/DB9 communications and optional network management card support for remote monitoring.


 

Tripp Lite SmartPro SM2200RMXL2UP UPS 2200VA 1920W, RM, 20A, 120V, AVR - User's Manual

 

SM2200RMXL2UP - Tripp Lite SmartPro UPS Specifications:

Main:

Main Input Voltage

120V AC

Main Output Voltage

120V

Rated Power in W

1920W

Rated Power in VA

2200VA

Input Connection Type

NEMA 5-20P

Output Connection Type

(4) NEMA 5-15R, (4) NEMA 5-15/20R

Number of Rack Unit

2U

Cable Length

10 ft (3.1 m)

Number of Cables

1

Battery Type

VRLA (Lead-Acid, Hot-Swappable)

 

 

 

General:

Number of Power Module Filled Slots 0
Number of Power Module Free Slots 0
Redundant No
Topology Line-Interactive
Waveform Type Pure Sine Wave
Power Factor 0.87
Efficiency (Line Mode) 96%

 

 

Input:

Efficiency at Full Load Up to 96% line-mode efficiency
Input Voltage Range (AVR) 83V – 145V (Automatic Voltage Regulation)
Input Frequency 60 Hz ±3 Hz
Input Current 16A max
Recommended Electrical Service 20A 120V
Input Phase Single-Phase
Efficiency (Line Mode) 96%

 

 

 

 

Batteries & Runtime:

Extendable Run Time

Yes

Included Battery Modules

Internal VRLA battery system

Battery Slots Empty

0

Typical Recharge Time

<4.5 hours (10–90%)

Battery Life

3–5 years typical

Replacement Battery

RBC94-2U

Battery Runtime Full Load

4.5 min (1920W)

Battery Runtime Half Load

12 min (960W)

 

Communications & Management:

Control Panel

LCD display with load, battery, status & configuration

Emergency Power Off (EPO)

Yes

Free Slots

1 SmartSlot

Alarm

Battery, overload, low battery, fault alarms

Network Management Slot

Yes (SmartSlot)

Serial Port

DB9 (RS-232)

USB Port

Yes (HID-compliant)

Communication Interfaces

USB, RS-232, SmartSlot, EPO

Remote Monitoring

Supported via optional network card

Software Compatibility

PowerChute Business Edition / PowerAlert

Watchdog / Auto-Reboot

Supported

Monitoring Functions

Voltage, load, battery status, diagnostics

Event Logging

Yes (via software / SNMP)

Remote Access

Full SNMP/Web (with card)

Firmware Updates

Via network card

 

 

 

User Interface, Alerts & Controls:

 
Front Panel Display

LCD status screen with detailed UPS data

Front Panel Indicators

Online, battery, overload, replace battery

Controls

Power ON/OFF, self-test, alarm mute

Audible Alarm

Battery mode, overload, low battery, fault

Alarm Management

Configurable

Emergency Power Off (EPO)

Supported

Control Interface Type

LCD + push button interface

 

 

 

Surge Protection and Filtering:

 
Surge Energy Rating

570 Joules

 

Physical:

Color

Black

Height

3.5 in (8.89 cm)

Width

17.5 in (44.45 cm) 

Depth

19.0 in (48.26 cm)

Net Weight

64 lb (29.03 kg)

Mounting Location

4-Post Rack

Mounting Preference

Standard Rack

Mounting Mode

Rack-mounted

Two Post Mountable

No

USB Compatible

Yes

Â