Tripp Lite Smart-Online 1500VA 1350W RM 2U LCD
Model: SUINT1500LCD2U
Input: C14 (200/208/220/230/240V)
Output: (6) C13
Double Conversion Online UPS - Sine wave Output
New Batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: Tripp Lite
Model: Tripp Lite Smart-Online 1500VA 1350W RM 2U LCD
Condition: New Batteries, Refurbished UPS
Part Number: SUINT1500LCD2U
Maximum output: 1350W / 1500VA
Typical backup time at half load:12.6 minutes (675 Watts)
Typical backup time at full load: 4.5 minutes (1350 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartOnline 1500VA 1350W RM 2U 120V SUINT1500LCD2U - User Manual
SUINT1500LCD2U Â - Tripp Lite SmartOnline 1500VA Specifications:
Input:
|
Rated input current (Maximum Load) |
7.49A |
||
|
Nominal Input Voltage(s) Supported |
200V AC; 208V AC; 220V AC; 230V AC; 240V AC |
||
|
UPS Input Connection Type |
|
||
|
Input Phase |
Single-Phase |
Output:
|
Output Volt Amp Capacity (VA) |
1500 |
|
Output Capacity (kVA) |
1.5 |
|
Output Watt Capacity (Watts) |
1350 |
|
Output kW Capacity (kW) |
1.35 |
|
Output Capacity Details |
DE-RATING INFORMATION: Max output in Frequency Conversion mode is reduced to 945 watts for |
|
Power Factor |
0.9 |
|
Crest Factor |
3:1 |
|
Nominal Voltage Details |
Nominal output voltage is user configured on first power-on |
|
Frequency Compatibility |
50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion |
|
Frequency Compatibility Details |
Output frequency matches input nominal on startup; Output capacity de-rates by 30% during frequency conversion operation |
|
Output Voltage Regulation (Line Mode) |
+/- 2% |
|
Output Voltage Regulation (Economy Line Mode) |
+/- 10% |
|
Output Voltage Regulation (Battery Mode) |
+/- 2% |
|
Load Management Receptacles |
Two switchable outlet load banks (2 NEMA 6-15/20R outlets per bank) |
|
Output AC Waveform (AC Mode) |
Pure Sine wave |
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
|
Nominal Output Voltage(s) Supported |
200V; 208V; 220V; 230V; 240V |
|
Output Receptacles |
(6) C13 outlets |
|
Individually Controllable Load Banks |
Yes |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Full Load Runtime (min.) |
4.5 minutes (1350W) |
|
Half Load Runtime (min.) |
12.6 minutes (675W) |
|
Expandable Battery Runtime |
Supports external battery packs such as BP36V15-2U and BP36V27-2US for extended runtime capabilities. |
|
Expandable Runtime |
Yes |
|
Expandable Runtime Description |
External battery configurations require the use of Tripp Lite's External Battery Configuration Software, see manual for details |
|
DC System Voltage (VDC) |
36V |
|
Battery Recharge Rate (Included Batteries) |
Less than 5.8 hours from 10% to 90% (typical, full load discharge) |
|
Battery Access |
Front panel battery access door |
|
Internal UPS Replacement Battery Cartridge |
RBC36S |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Online, double-conversion power conditioning |
|
Overvoltage Correction |
Corrects output voltage regulation during overvoltages to 288V with a tolerance of +/- 2% |
|
Undervoltage Correction |
160V at 100% load |
User Interface, Alerts & Controls:
|
Front Panel LCD Display |
Interactive LCD interface provides UPS operating mode, detailed UPS status, and site-power information. |
|
Switches |
Five front panel switches: On/Off, Up, Down, and Escape. |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced by following on-screen prompts |
|
Audible Alarm |
Alerts for power failure, low battery, overload, and fault conditions. |
| LED Indicators                     |
AC input (green): Indicates the presence of utility power input.AC output (green): Indicates the availability of AC power output from the UPS. |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
936 Joules |
|
UPS AC Suppression Response Time |
Instantaneous |
|
UPS Dataline Suppression |
Single line dialup / network dataline protection included |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Primary Form Factor |
Rackmount
|
|
Cooling Method |
Fan
|
|
Primary UPS Depth (mm) |
496 mm |
|
Primary UPS Height (mm) |
88 mm |
|
Primary UPS Width (mm) |
438 mm |
|
Shipping Dimensions (hwd / cm) |
24.00 x 57 x 70.00 cm |
|
Shipping Weight (kg) |
26.31 kg |
|
Shipping Weight (lbs.) |
58 lbs. |
|
UPS Housing Material |
Metal |
|
UPS Power Module Dimensions (hwd, cm) |
9 x 44 x 50 cm |
|
UPS Power Module Weight (kg) |
20.36 |
Â
Environmental:
|
Operating Temperature Range |
 0°C to 40°C (32°F to 104°F)
|
|
Storage Temperature Range |
-15°C to 50°C (5°F to 122°F) |
|
Relative Humidity |
5 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
330 BTU/hr |
|
Battery Mode BTU / Hr. (Full Load) |
689 BTU/hr |
|
AC Mode Efficiency Rating (100% Load) |
>93% |
|
Audible Noise |
<45dB at front side, 1 meter |
|
Operating Elevation (m) |
0-10000 ft. (0-3000 m) |
Communications:
|
Network Management Cards |
WEBCARDLXÂ |
|
Network Monitoring Port Description |
Includes ports such as RS-232 and USB for local monitoring and management. |
|
PowerAlert Software |
Free downloadable PowerAlert software enables safe unattended file saves and system shutdown during prolonged power failures. https://tripplite.eaton.com/products/power-alert |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network Management Card Description |
Network management card optional |
|
Communications Interface |
Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled) |
Â