Tripp Lite SmartPro 5000VA 3750W RM 3U
Model: SMART5000TEL3U
Input:Â NEMA L6-30PÂ (208V - 30A)
Output: (2) NEMA 5-15R, (2) NEMA L6-20R, (1) NEMA L6-30R
Line Interactive UPS - Sinewave Output
New batteries, Refurbished UPS
1 Year Warranty Included
Back Order
Manufacturer: Tripp Lite
Model: Tripp Lite SmartPro UPS 5000VA 3750W, RM, 3U, 208V
Condition: New batteries, refurbished UPS
Part Number: SMART5000TEL3U
Maximum output: 3750W / 5000VA
Typical backup time at half load:20 minutes (1875 Watts)
Typical backup time at full load: 8.5 minutes (3750 Watts)
Warranty: 1 year full replacement warranty
Tripp Lite SmartPro 5000VA 3750W RM 208V SMART5000TEL3U - User Manual
SMART5000TEL3U - Tripp Lite SmartPro 5000VAÂ Specifications:
Input:
|
Rated input current (Maximum Load) |
24A |
||
|
Nominal Input Voltage(s) Supported |
208V AC |
||
|
UPS Input Connection Type |
|
||
|
Input Circuit Breakers |
15A |
||
|
UPS Input Cord Length (ft.) |
10 |
||
|
UPS Input Cord Length (m) |
3.1 |
||
|
Recommended Electrical Service |
30A 208V |
||
|
Input Phase |
Single-Phase |
Output:
|
Output Volt Amp Capacity (VA) |
5000 |
||||||
|
Output Capacity (kVA) |
5 |
||||||
|
Output Watt Capacity (Watts) |
3750 |
||||||
|
Output kW Capacity (kW) |
3.75 |
||||||
|
Output Capacity Details |
120V 5-15R outlets are limited to 450 watts (max.) |
||||||
|
Power Factor |
0.75 |
||||||
|
Nominal Voltage Details |
120V output is limited to 450 watts |
||||||
|
Frequency Compatibility |
60 Hz |
||||||
|
Output Voltage Regulation (Line Mode) |
208 & 120V (-6%, +20%) |
||||||
|
Output Voltage Regulation (Battery Mode) |
+/- 5% |
||||||
|
Output Circuit Breakers |
20A double pole breaker supports L6-20R outlets, 5A breaker supports 5-15R outlets, L6-30R outlet is unbreakered |
||||||
|
Output AC Waveform (AC Mode) |
Sine wave |
||||||
|
Output AC Waveform (Battery Mode) |
Pure Sine wave |
||||||
|
Nominal Output Voltage(s) Supported |
208V |
||||||
|
Output Receptacles |
|
||||||
|
Individually Controllable Load Banks |
No |
Battery:
|
Battery Type |
Valve Regulated Lead Acid (VRLA) |
|
Full Load Runtime (min.) |
8.5 min. (3750w) |
|
Half Load Runtime (min.) |
20 min. (1875w) |
|
Expandable Runtime |
No |
|
DC System Voltage (VDC) |
48 |
|
Battery Recharge Rate (Included Batteries) |
Less than 4 hours from 10% to 90% (typical, full load discharge) |
|
Battery Access |
Front panel battery access door |
|
Internal UPS Replacement Battery Cartridge |
RBC94-3UÂ (quantity 3) |
|
Battery Replacement Description |
Hot-swappable, user replaceable batteries |
Voltage Regulation:
|
Voltage Regulation Description |
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 167 to 260 |
|
Overvoltage Correction |
Input voltages between 228V and 260V are reduced by 12% |
|
Undervoltage Correction |
Input voltages between 167V and 194V are boosted by 12% |
User Interface, Alerts & Controls:
|
Switches |
2 Switches control off/on power status and alarm-cancel/self-test operation |
|
Alarm Cancel Operation |
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate lowbattery status |
|
Audible Alarm |
Audible alarm indicates power-failure, overload and low-battery conditions |
|
LED Indicators |
5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status |
Surge / Noise Suppression:
|
UPS AC Suppression Joule Rating |
1020 |
|
UPS AC Suppression Response Time |
Instantaneous |
|
EMI / RFI AC Noise Suppression |
Yes |
Physical:
|
Primary Form Factor |
Rackmount |
|
Cooling Method |
Fan |
|
Installation Form Factors Supported with Included Accessories |
4 post 19 inch rackmount |
|
Installation Form Factors Supported with Optional Accessories |
2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND ) |
|
Minimum Required Rack Depth (cm) |
76.20 |
|
Minimum Required Rack Depth (inches) |
30 |
|
Primary UPS Depth (mm) |
635 |
|
Primary UPS Height (mm) |
133 |
|
Primary UPS Width (mm) |
445 |
|
Rack Height |
3U |
|
Shipping Dimensions (hwd / cm) |
30.48 x 58.42 x 83.82 |
|
Shipping Dimensions (hwd / in.) |
12.00 x 23.00 x 33.00 |
|
Shipping Weight (kg) |
82.55 |
|
Shipping Weight (lbs.) |
182.00 |
|
UPS Housing Material |
Steel |
|
UPS Power Module Dimensions (hwd, cm) |
13.34 x 44.45 x 63.50 |
|
UPS Power Module Dimensions (hwd, in.) |
5.25 x 17.5 x 25 |
|
UPS Power Module Weight (kg) |
65.00 |
|
UPS Power Module Weight (lbs.) |
143.3 |
Environmental:
|
Operating Temperature Range |
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
|
|
Storage Temperature Range |
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
|
Relative Humidity |
0 to 95%, non-condensing |
|
AC Mode BTU / Hr. (Full Load) |
366 |
|
Battery Mode BTU / Hr. (Full Load) |
1423 |
|
AC Mode Efficiency Rating (100% Load) |
97% |
|
Audible Noise |
45 dBA maximum, front side 1m |
Communications:
|
Network Management Cards |
SNMPWEBCARDÂ ; Â TLNETCARDÂ ; Â WEBCARDLX |
|
Network Monitoring Port Description |
Supports detailed monitoring of UPS and site power conditions |
|
PowerAlert Software |
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert |
|
Communications Cable |
USB and DB9 cabling included |
|
WatchDog Compatibility |
Supports Watchdog application, OS and hard-reboot restart options for remote applications |
|
Network Management Card Description |
Network management card optional |
|
Communications Interface |
Contact closure; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB |