Vertiv GXT5 5kVA 5kW RM/Tower 5U 208V 50A
Model: GXT5-5000HVRT5UXLN
Input:Â Hardwire (208V/240V) - L1-L2-G
Output: (2) L6-20R, (2) L6-30R, Hardwire
Online, Double-Conversion UPS - Sine wave Output
New batteries, refurbished UPS
1 Year Warranty Included
In stock
Manufacturer: Vertiv
Model: Vertiv Liebert GXT5 5000VA 5000W RM/Tower 5U 208V/240V - Online Double Conversion UPS
Condition: New batteries, refurbished UPS
Part Number: GXT5-5000HVRT5UXLN
Maximum output: 5000W / 5000VA
Typical backup timeat half load: 18.5 minutes (2500 Watts)
Typical backup time at full load: 7 minutes (5000 Watts)
Warranty: 1 year full replacement warranty
Included: UPS, preinstalled RDU101 NIC, rack ears, rail kit, tower stand (feet), USB cable
Vertiv GXT5 5000VA 5000W GXT5-5000HVRT5UXLN User's Manual
GXT5-5000HVRT5UXLN - Vertiv UPS 5000VA / 5000W Specifications:
Overview:
|
Power Rating |
5,000VA / 5,000W |
|
Input Voltage |
Typical: 208VAC / Range: 176-288VAC - L1-L2-G |
|
Output Voltage |
200/208/220/230/240 VAC (user-configurable) |
|
Efficiency |
Up to 98% Active ECO Mode; up to 95% on-line mode |
|
Wiring |
Hardwired in/out + Output: 2 x L6-20R, 2 x L6-30R |
Operational Conditions:
|
Operating Temperature |
+32 to +104 °F (0 to 40 °C) |
Physical:
|
Dimensions (inch/mm) |
16.9 × 24.8 × 8.5 (430 × 630 × 217) |
|
Weight (lbs/kg) |
156.7 (71.1) |
Input AC:
|
Operating Frequency, Nominal |
50 or 60 Hz |
|
Factory-default VAC |
208 VAC - L1-L2-G |
|
User-configurable VAC |
200/208/220/230/240 VAC (Adjustable using operation/display configuration options) |
|
Operating voltage range without battery operation |
176 – 288 VAC (100 – 176VAC with power derating) |
|
Maximum Allowable VAC |
288 VAC |
|
Input Frequency without Battery Operation |
40 – 70 Hz |
|
Voltage Range |
176 – 288 VAC (100 – 176 VAC |
|
Input Power Connection |
PD5-CE6HDWRMBSU |
Output AC:
|
Output Receptacles |
|
||||
|
Output Power Connection |
PD5-CE6HDWRMBSU |
||||
|
AC-AC Efficiency |
94% |
||||
|
Factory-default VAC Frequency |
208 VAC, 60 Hz |
||||
|
Output Voltage |
208 VAC Nominal |
||||
|
Waveform |
Sinewave |
||||
|
Normal Mode Overload |
>150% minimum 200 mS |
Interfaces / Ports:
|
Interface Options |
Factory pre-installed Vertiv™ RDU101 SNMP/Webcard, USB, RS485, RS232, terminal block, external battery connector |
|
Protocols |
SNMP and web management enabled with factory pre-installed Vertiv RDU101 communications card; serial connection for out-of-band management |
|
Control Panel |
Full-color graphic LCD with gravity sensing orientation, provides insight to UPS status for easy installation, configuration and operation |
Internal Battery Charger:
|
Charger Current, A |
2.25A default, maximum 5A |
Battery Parameters:
|
Type |
Valve-regulated, non-spillable, lead acid |
|
Quantity x Voltage x Rating |
16 x 12V x 9.0AH |
|
Upper-limit selections |
+10%, +15%, +20%; default +10%. |
|
Lower-limit selections |
-10%, -15%, -20%; default -15% |
|
Disable-bypass operation |
-10%, -15%, -20%; default -15% |
|
Backup Time (100% Load) |
7.0 Minutes |
|
Backup Time (50% Load) |
18.5 Minutes |
|
+1 External Battery Cabinet (100% Load) |
19.0 Minutes |
|
+1 External Battery Cabinet |
48.0 Minutes |
Environmental:
|
Operating Temperature, °F (°C) |
+32 to +104 (0 to 40) |
|
Storage Temperature, °F (°C ) |
+5 to +104 (-15 to 40) |
|
Relative Humidity |
0 to 95%, non-condensing |
|
Operating Elevation |
Up to 10,000 ft (3,000 m) at 77°F |
|
Audible Noise |
<55 dBA,at 1 meter from the front, |
Agency:
|
Safety |
IEC62040-1:2008 version |
|
EMI/EMC/C-Tick EMC |
IEC/EN/AS 62040-2 2nd |
|
ESD |
IEC/EN EN61000-4-2 |
|
Radiated Susceptibility |
IEC/EN EN61000-4-3 |
|
Electrical Fast Transient |
IEC/EN EN61000-4-4 |
|
Surge Immunity |
IEEE/ANSI C62.41 |
|
Transportation |
ISTA Procedure 1E |
|
Emissions |
FCC Part 15 (Class A) |
Miscellaneous:
|
Listings |
ENERGY STAR® 2.0 certified, UL1778, c-UL listed, RoHS2, REACH |
|
Topology |
On-line double conversion UPS; flexible rack/tower form factor |