Vertiv Liebert GXT5 UPS 2000VA 1800W Lithium-ion 120V GXT5LI-2000LVRT2UXL - Refurbished

Vertiv Liebert GXT5 2000VA 1800W RM 2U 120V - 
Model: GXT5LI-2000LVRT2UXL
Input: NEMA L5-20P 20A - 120V
Output: (1) L5-20R, (6) 5-15/20R
Online, Double-Conversion UPS - Sine wave Output
New batteries, refurbished UPS
1 Year Warranty Included

Back Order

Manufacturer: Liebert
Model:
 Liebert GXT5 2000VA 1800W, RM, 2U, 120V 20A
Condition:
New batteries, refurbished UPS
Part Number:
GXT5LI-2000LVRT2UXL

Maximum output: 1800W / 2000VA
Warranty: 1 year full replacement warranty
Includes: (1) GXT5LI-2000LVRT2UXL UPS - No additional accessories are included


Liebert GXT5 2000VA 1800W RM 2U GXT5LI-2000LVRT2UXL - User's Manual


GXT5LI-2000LVRT2UXL - Liebert GXT5 2000VA Specifications:

Output:

Output Power Capacity

1800W / 2000VA

Typical 120V User Selectable Output

110/115/120VAC (user-configurable); ±3%

Waveform Type

Sine wave

Output Connections

(1) NEMA L5-20R

 

(6) NEMA 5-15/20R

 

Utility (AC) Mode Overload

>200% for 250ms;
150- 200% for 2 seconds;
125- 150% for 50 seconds;
105-125% for 60 seconds


Input:

Range

Typical 120V
Range: 60-150V

Frequency

40-70Hz; Auto Sensing

Input Power Connection

NEMA L5-20P

 

Nominal Voltage Setting

120VAC Default;
100/110/115/120V/125VAC
(User-Configurable)

Surge Protection

ANSI C62.41, Category B


Batteries and Runtime:

Type

Lithium-Ion (LiFePO4)

Recharge Time (from full discharge)

< 2 hrs to 90% 

Full-Load Runtime

10.5 min

Half-Load Runtime

22.5 min

External Battery Cabinet

VEBCLI-48VRT1U


Environmental:

Operating Temperature °F(°C)

32°F to 104°F (0°C to 40°C) (10% Derating
at 50°C)

Storage Temperature°F(°C)

-4° to 140° (-20° to 60°)

Audible Noise

< 48 dB

Relative Humidity

0% to 95%, non-condensing

Operating Elevation

0 to 10,000 (0 to 3,000) w/o Derating
(15% Derating at 4000m)


Agency:

Safety

UL 1642 (Li-Ion Battery Cells), UL 1973
(Li-Ion Battery Pack w/UPS), UL 1778, CSA
22.2 No. 107.3

Environmental

RoHS2 / REACH / WEEE

Network Surge

IEC 61000-4-5, ANSI C62.41, Category B

Transportation

ISTA Procedure 2A


Communications and Management:

Interface port

USB, Intellislotâ„¢ web card for SNMP and web management.
Supports environmental sensors

Available Slot Interface Quantity

1

 

 

UPS manageability options

Vertivâ„¢ Power Insight is a complimentary web-based software
designed to monitor up to 100 Vertivâ„¢ UPSs and rPDUs


Physical:

Maximum Height

3.4 inches (85 mm)

Maximum Width

16.9 inches (430 mm)

Maximum Depth

18.5 inches (470 mm)

Net weight

47.5 lbs. (21.6 kg)