Call toll free: 1-866-311-1945 | sales@excessups.ca
Your Region:

Tripp Lite SmartPro 2200VA 1700W Tower 120V SMART2200NET - Refurbished

Tripp Lite SmartPro 2200VA 1700W Tower
Model: SMART2200NET
Input: NEMA 5-15P  (120V - 15A)
Output: (6) NEMA 5-15R
Line-Interactive UPS - Sine wave Output
New batteries, Refurbished UPS
1 Year Warranty Included

Usually ships in 15-20 days

Usually ships in 15-20 days

Usually ships in 15-20 days

CAD $549.99
Availability: On backorder

Usually ships in 15-20 days

Description

Details

Manufacturer: Tripp Lite
Model:
Tripp Lite SmartPro UPS 2200VA 1700W, Tower, 120V
Condition:
New batteries, refurbished UPS
Part Number:
SMART2200NET

Maximum output: 1700W / 2200VA
Typical backup time
at half load: 27 minutes (850 Watts)
Typical backup time
at full load: 11 minutes (1700 Watts)
Warranty:
1 year full replacement warranty


Tripp Lite SmartPro 2200VA 1700W Tower 120V SMART2200NET Manual


SMART2200NET - Tripp Lite SmartPro Specifications:

Input:

Rated input current (Maximum Load)

15A

Nominal Input Voltage(s) Supported

120V AC

UPS Input Connection Type

(1) NEMA 5-15P

Input Circuit Breakers

20A

UPS Input Cord Length (ft.)

8

Recommended Electrical Service

20A 120V

Input Phase

Single-Phase

Input Cord Length (ft.)

8


Output:

Output Volt Amp Capacity (VA)

2200

Output kVA Capacity (kVA)

2.2

Output Watt Capacity (Watts)

1700

Output kW Capacity (kW)

1.7

Output Capacity Details 

Output is reduced to 1200W maximum with 1-2 external battery packs and 800W maximum with 3 or more external
battery packs

Power Factor

0.8

Nominal Voltage Details

120v nominal output in battery mode

Frequency Compatibility

60 Hz

Output Voltage Regulation (Line Mode) 

-13% / +5%

Output Voltage Regulation (Battery Mode)

+/- 5%

Load Management Receptacles

Two switchable single outlet 5-15R load banks

Output AC Waveform (AC Mode)

Sine wave

Output AC Waveform (Battery Mode)

PWM sine wave

Nominal Output Voltage(s) Supported

110V; 115V; 120V

Output Receptacles

(6) NEMA 5-15R

Individually Controllable Load Banks

Yes


Battery:

Full Load Runtime (min.)

11 min. (1700w)

Half Load Runtime (min.)

27 min. (850w)

Expandable Battery Runtime

Extended runtime supported via optional external battery packs

Expandable Runtime

Yes

External Battery Pack Compatibility

BP24V28-2U  (limit 1);  BP24V70-3U  (multi-pack compatible)

DC System Voltage (VDC)

24

Battery Recharge Rate (Included Batteries) 

Less than 9 hours from 10% to 90% (typical, full load discharge)


Voltage Regulation:

Voltage Regulation Description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 87 to 140

Overvoltage Correction

Input voltages between 127 and 140 are reduced by 12%

Undervoltage Correction

Input voltages between 95 and 105 are boosted by 10%

Severe Undervoltage Correction

Input voltages between 87 and 94 are boosted by 22%


User Interface, Alerts & Controls:

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation; set of 4 rear-panel switches control system enable and contact closure port inverter shutoff commands

Alarm Cancel Operation

Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate lowbattery status

Audible Alarm 

Audible alarm indicates power-failure and low-battery conditions

LED Indicators

5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status


Surge / Noise Suppression:

UPS AC Suppression Joule Rating

720

UPS AC Suppression Response Time

Instantaneous

EMI / RFI AC Noise Suppression

Yes


Physical:

Primary Form Factor

Tower

Primary UPS Depth (mm)

318

Primary UPS Height (mm)

432 

Primary UPS Width (mm)

229

UPS Housing Material

Polycarbonate

UPS Power Module Dimensions (hwd, in.)

17 x 9 x 12.5

UPS Power Module Weight (kg)

36.29

UPS Power Module Weight (lbs.)

80


Environmental:

Operating Temperature Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC Mode BTU / Hr. (Full Load)

59

Battery Mode BTU / Hr. (Full Load)

867

AC Mode Efficiency Rating (100% Load)

99%


Communications:

Network Monitoring Port Description

Supports detailed monitoring of UPS and site power conditions; contact closure communications via two additional DB9 ports (3 total)

PowerAlert Software

For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://www.tripplite.com/poweralert

Communications Cable

3 DB9 cables included

Network Management Card Description

Network management not supported

Communications Interface

Contact closure; DB9 Serial

Additional Info

Additional Info

Manufacturer Tripp Lite
Form Factor Tower
Waveform in Battery Mode Pure Sinewave
Input Voltage 120V AC
Output (VA) 2200VA
Output Voltage 120V AC
PDU Total Outlets No